Peripheral Devices
450
9836 3521 01
Parameter
Id
Bytes
Implementation
Time
15
19
YYYY-MM-DD:HH:MM:SS
Sync
tightening Id
16
5
The sync tightening Id is a unique Id for each sync tightening result.
Each individual result of each spindle is stamped with this Id.
The tightening Id is incremented after each sync tightening. 5 ASCII digits.
Max 65 535. Reports Station DataNo, created when cycle is ready.
Sync overall
status
17
1
Reports 1 when station status is OK or OKR. Reports 0 when station status
is NOK, TERMNOK or NOKRM.
Spindle
status
18
18
Number
of
spindles
Bytes 1-2: Ordinal bolt number (01
–99)
Bytes 3-4: Spindle number (01-99)
Byte 5: Reports 0 when bolt status is NOK, NOKRM or TERMNOK. Reports 1
when bolt status is OK or OKR.
Byte 6: Reports 0 if bit CD_ERR_FTLM set for ErrorCode. Equally 2 is
reported if FTHM set. If neither FTLM nor FTHM is set 1 is reported
Bytes 7-12: Bolt T from the Monitor function for current bolt. Same format as
Torque Min limit is reported in.
Byte 13: Equal to Byte 6, but looks at bit ALM and AHM.
Byte 14-18: Bolt A from the Monitor function for current bolt. Same format as
Angle Min limit is reported in.