Peripheral Devices
468
9836 3521 01
8.11.4.9 TC Result Formats for PDT
The tightening results are reported to PLUS according to the specification.
Station data:
Field
Implementation
QUALITÄTSAUSSAGE-ORTS-NR
QO
Station QO in the cycle data.
JOB-NR
JN
Mode number for the tightening.
GESAMT-Q-AUSSAGE
GQ
Station status of a tightening.
1 = OK is sent for status OK and OKR (OK after repair)
0 = NOK is sent for status NOK and TERMNOK (failed
during termination).
GESAMT-STATUS
GS
Always 0
SOLL-ANZAHL-EINZELERGEBNISSE
SA
Station SA in the cycle data.
EINZELERGEBNIS-TYP-KZ
ET
The value in
Station ET.
Bolt data:
Field
Implementation
EINZELERGEBNIS-NR
EN
Bolt number from ToolsTalk PowerMACS setup.
EINZELERGEBNIS-IDENT
EI
Bolt name from ToolsTalk PowerMACS setup. The bolt
number will be added at the end of the bolt name to reach 24
characters.
EINZELERGEBNIS-Q-AUSSAGE
EQ
Bolt status for this tightening
1 = OK is sent for status OK and OKR (OK after repair)
0 = NOK is sent for status NOK, TERMNOK (failed during
termination) and NOKRM (not successful due to reject
management)
EINZELERGEBNIS-STATUS
ES
Always 0
EINZELERGEBNIS-QA-DETAIL
ED
Customer Error Code in the cycle data.
ANLAGEN-ORTS-NR
AO
Will always be the same as QO for all bolts.
ANLAGEN-BETREIBER
AB
Station AB in the cycle data, always the same for all bolts.
USER-ID
US
Id Res 4 in the cycle data, always the same for all bolts.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...