Set Up and Maintenance
206
9836 3521 01
Change Net Data form.
Press the
Download
button to prepare download of System Software using the form Prepare TC for
To enable the telnet interface on a TC klick the
Telnet
menu item.
Note
The Telnet server is only used for advanced debugging purposes and
should normally be
switched off
during normal operations.
You should not activate it unless directed by Atlas
Copco personal to do so
.
The server is automatically disabled whenever the TC is restarted.
This command requires that the Console Computer is on the same network as the target system(s)
to modify, or there must exist a route between them.
For new net data, or a download to be effective, the TC must be restarted. Turning the power off and on
again is the normal way to do this. But if at least one TC accepts the request you will be offered the
possibility to restart those TCs remotely. You should only restart the TCs remotely if you are absolutely
sure that it is safe for the system to do so.
To overwrite spindle software with spindle software stored in TC flash, klick
Load spindle SW from TC
.
This is only needed when wanting to downgrade the software in the spindle. TC automatically upgrades
the spindle upon start of communication if the spindle software in TC is newer than the software in the
spindle.
To overwrite servo software with servo software stored in TC flash, klick
Load servo SW from TC
. This is
only needed when wanting to downgrade the software in the servo. TC automatically upgrades the servo
upon start of TC if the servo software in TC is newer than the software in the servo.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...