Appendix
9836 3521 01
631
Code
Comp
Code
Type
Severity Event string
845
180
Check
Error
Step %d, Monitoring: Yield point angle diff. %f < %f
846
181
Check
Error
Step %d, Check: Torque rate %.4f > %.4f
847
182
Check
Error
Step %d, Check: Torque rate %.4f < %.4f
848
183
Check
Error
Step %d, Check: Deviation %f > %f
849
184
Check
Error
Step %d, Check: Torque Rate calculation failed
850
185
Check
Error
Step %d, Check: Overflow in Torque Rate recording buffer
851
186
Setup
Error
Step %d, Check: Torque rate/deviation has bad configuration
852
423
Setup
Info
Step %d, Retry is ordered but this step has no retry step
programmed
853
426
Check
Error
Step %d, Check: Angle failed because Torque stop was never
reached
854
427
Check
Error
Step %d, Monitoring: Torque level stop for Threshold angle was
never reached
863
460
Setup
Error
Step %d, Control: Start cond. "Sync Pulse" requires Angle 2 as
control channel
875
478
System
Error
Step %d, Received illegal Retry order in SP_RUN_STEPS from
station. (Spindle running %d.)
876
479
Check
Error
Step %d, Check: Peak torque failed.
878
481
Check
Error
Step %d, Diagnostic: Static Zero Offset high on T2. abs(%f) > %f
879
482
Check
Error
Step %d, Diagnostic: Dynamic Zero Offset high on T2. abs(%f) >
%f
880
483
Check
Error
Step %d, Diagnostic: Flying Zero Offset high on T2. abs(%f) >
%f
881
484
Check
Warning
Step %d, Diagnostic: Flying Zero Offset high warning on T2.
abs(%f) > %f
883
531
Setup
Error
Step %d, Control: Torque-Angle step has bad configuration
884
532
Setup
Error
Step %d, Restriction: Start torque for FS Angle has bad
configuration
885
533
Setup
Error
Step %d, Restriction: Start condition for FS Angle has bad
configuration
887
535
Check
Error
Step %d, Monitoring 2nd: Final torque could not be evaluated
888
536
Check
Error
Step %d, Monitoring 2nd: Threshold angle could not be
evaluated
889
537
Check
Error
Step %d, Monitoring 2nd: Final torque. %f > %f
890
538
Check
Error
Step %d, Monitoring 2nd: Threshold angle. %f > %f
891
539
Check
Error
Step %d, Monitoring 2nd: Final torque. %f < %f
892
540
Check
Error
Step %d, Monitoring 2nd: Threshold angle. %f < %f
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...