Appendix
632
9836 3521 01
Code
Comp
Code
Type
Severity Event string
893
541
Check
Error
Step %d, Monitoring 2nd: Torque level stop for Threshold angle
was never reached
894
542
Setup
Info
Monitoring 2nd buffer: No second channels. 2nd buffer used in
check %d, step %d.
895
549
Setup
Error
Step %d, Restriction: Incorrect FS Min torque configuration
897
555
Setup
Error
Step %d, Restriction: Incorrect Gradient restriction configuration
898
683
Setup
Error
Step %d, Check: Incorrect Yield Point Check configuration
899
690
Check
Error
Step %d, Diagnostic: Spindle shunt test failed on channel %d
901
187
Check
Error
Step %d, Restriction: Fail-safe torque
902
188
Check
Error
Step %d, Restriction: Fail-safe angle
903
189
Check
Error
Step %d, Restriction: Fail-safe time
905
191
Check
Error
Step %d, Restriction: Cross thread and gradient
906
192
Check
Error
Step %d, Restriction: Torque profile
907
193
Check
Error
Double transducer: torque diff high
908
194
Check
Error
Double transducer: angle diff high
909
195
System
Error /
Info
Monitoring: Overflow in recording buffer %d
910
196
Hardware
Error
Step %d, Servo hardware failure, Id %d
911
197
Setup
Error
Incorrect Servo configuration
917
203
System
Error
No Snug point was found
918
440
Check
Error
Step %d, Restriction: Remove fastener torque limit
923
529
Check
Error
Spindle protection: Max allowed torque for spindle exceeded
924
550
Check
Error
Step %d, Restriction: Min Torque
925
556
Check
Error
Step %d, Restriction: Gradient too high
926
557
Check
Error
Step %d, Restriction: Gradient too low
927
558
Check
Error
Step %d, Restriction: Gradient error as angle decreased
929
684
Check
Warning
Step %d, Check YP: Gradient calculation restarted as angle
decreased
930
934
Check
Error
Step %d, Fatal continue rotation error, was not handled by reject
management
931
935
Check
Error
Step %d, Restriction error during continue rotation
932
936
Setup
Warning
Step %d, Continue rotation is not allowed at step start, spindle
was stopped
933
937
Setup
Warning
Step %d, Direction changed during Continue rotation
1001
553
System
Error
Trace: Unable to store new trace on TC %d, too many saved
traces
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...