Peripheral Devices
510
9836 3521 01
8.12.3.2 Profibus DP and DP-V1
The Anybus-CC Profibus communication module provides instant
Profibus Real Time connectivity via the host interface and supports the
following features:
Profibus communication, with baud rates 12 Mbps (auto detect by
the module)
Up to 152/244 bytes of Real Time I/O
Up to 8192 bytes of acyclic data such as cycle data, trace etc.
Acyclic data can be accessed from the network using DP-V1
read/write services.
Generic GSD-file.
Use
Name
to specify the name of the device. This name should be
referred to when you create a reporter for the fieldbus using the
New
reporter
form.
Fieldbus Type
should be set to DeviceNet.
Use
Node addr.
field to set the node address. Node address can be set
to [0..125].
See chapter:
PLC bytes In
,
PLC
bytes Out
,
Data bytes In
, and
Data bytes Out.
The parameter
Fast bytes In
defines the size (in bytes) of the input data
that is transferred as cyclic, or real time, IO data on the ProfiNet IO
network. Max value is
PLC bytes In
+
Data bytes In.
Leaving the
parameter "blank" will make all input data transfererred as cyclic IO data.
Fast bytes Out
defines the size (in bytes) of the output data that is
transferred as cyclic IO data on Profibus network. Max value is
PLC
bytes Out
+
Data bytes Out
. Leaving the parameter “blank" will make all output data transferred as cyclic
IO data.
The "
fast
" areas always start at offset zero (0) of the respective input or output area. The remaining part of
the respective areas is transferred as acyclic data.
The input as well as the output area of the Profibus module is divided in data blocks. The maximum size of
each block is 64 bytes. For example, if 400 bytes output is configured it will be available as seven blocks,
the first six contains 64 * 6 = 384 bytes and the seventh 16 bytes.
The parameter
Extended Mode
is a checkbox that chooses between the
152
bytes data mode and the
368
bytes data mode. When this checkbox is unchecked the backward compatible
152
bytes data mode is
chosen, and when checked the new
368
bytes data mode is chosen.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...