PLC
9836 3521 01
253
Activate the Boot project by pressing the
Activate
button.
Start the execution of the PLC by pressing the button
Cold
in the
Resource Control
dialog.
When your program is downloaded you can study current status of all signals in the program by using the
Debug
alternative in the PLC
Online
menu. If the program has not been compiled yet the PLC will
complain by saying, "Cannot switch to online mode because the project is not successfully compiled!" In
these cases just compile the program, and if there are errors, fix these. Then try to go on-line again.
Note 1
: Saving the project from inside the PowerMACS PLC does
not
implicate cause the PLC project to
be saved together with your setup on disk. To do that you must you choose
Save
, or
Save As
,
from the WinTC
File
menu.
Note 2
: It is the ZWT2 file that is regarded to be the source of the PLC project. It contains the project in
compressed form. Whenever you open a PowerMACS setup the PLC project is expanded to the
folder named
CurrentSetup
, which is located below the folder you installed PowerMACS in. Keep
in mind that this folder only is used as a temporary working folder. Whenever you save the setup
the PLC project is also compressed and saved to disk. When you go on-line and download a
setup to a system the ZWT2 is also downloaded.
For more details on how to program the PLC see the MULTIPROG wt manual.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...