Tightening
318
9836 3521 01
6.5.3.8 Angle Difference
Parameters
: Use spindle limits, Max difference, Number of samples
Function
:
Supervises Angle channel 1 readings compared to Angle channel 2 readings. The
restriction requires two angle channels to be equipped on the spindle.
Select if you want to use the spindle‟s stored limits or configure your own limits (
Max
difference
– Maximum difference in degrees,
Number of samples
–
For how many
samples (milliseconds) Max difference is allowed).
If a angle double transducer protection is configured on the spindle this restriction will
replace that during the step, see Angle Double Transducer Check.
Diagram
:
None
Alarms
:
Double Angle Transducer Error (ADIFF)
Trace
:
-
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...