Peripheral Devices
9836 3521 01
487
8.12.1.1 PLC Areas
Fieldbus input signals
Address: 3000-3299
Can in ToolsTalk be mapped for fieldbus when having prefix “SI_”.
Fieldbus output signals
Address: 3300-3599
Can in ToolsTalk be mapped for fieldbus and I/O when having prefix “SO_”.
Digital input signals
Address: 1600- 1791
Can in ToolsTalk be mapped only for I/O.
Digital output signals
Address: 1600- 1791
Can in ToolsTalk be mapped only for I/O.
Shared input signals
Address: 30000-30999
Can in ToolsTalk be mapped for for fieldbus and I/O
when having prefix “SI_”.
Shared output signals
Address: 30000-30999
Can in ToolsTalk be mapped for fieldbus and I/O
when having prefix “SO_”.
NOTE:
Only boolean signals can be mapped by I/O.