Peripheral Devices
604
9836 3521 01
8.16 ACTA 3000
The ACTA 3000 device enables calibration of the torque transducer for the spindles of your system using
the ACTA test equipment from Atlas Copco. One device enables calibration of all spindles in the station.
Add the device to the Station TC and make the physical connection of the ACTA unit to this TC.
Use
Name
to specify the name of the device.
Port
specifies which physical communication port that should be used. Port 2 is default and should be
used for the standard cables.
You can control whether or not cycles can be started from the PowerMACS PLC or the Test Bolts form
using the PLC System Globals Station variables ACTA_ACTIVE and DISBALE_ACTA.
The PLC program created by default (when no GM DeviceNet device is used) blocks out starts from the
PowerMACS PLC and the Test Bolts form.
The calibration can be run in two different modes, controlled by the ACTA or controlled by the TC.
Controlled by ACTA
If the calibration is controlled by the ACTA the cycles are started from the ACTA unit. In the ACTA unit you
have to specify the spindle and the mode number that shall be used. It is only this spindle that will run.
If mode 0 is selected a special program adapted to the QRTT equipment is used for the calibration. With
this program both the torque and angles can be verified and calibrated.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...