Tightening
342
9836 3521 01
Diagram:
Angle
Torque
TC
Shut off point
TTrig
TC
Threshold torque
1
– 4
Drops below trigger level
TTrig
Trigger level
Step
1
2
3
4
Result var.:
none
Alarms:
Stick slip detected (SS)
Trace
:
The torque trigger level is shown as a horizontal line from the first drop to the last. In
dynamic mode the line represents the maximum trigger level that was used. The line is only
shown when Torque vs. Angle is selected.
6.5.4.15 Delta T (only available for Gauging)
Parameters
:
TH
(Maximum delta torque),
TL
(Minimum delta torque).
Function:
The difference between the peak torque and the low spot torque, measured from check
start to check end is compared to the limits.
TH
is the high limit and
TL
is the low limit. Both
or only one of the limits can be programmed.
If the check operates on step it starts at step start. It ends when the step end, the last
sample is taken at the shut off point of the step. If the check operates on zone the check
start when the selected zone starts and ends when the zone ends.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...