Tightening
9836 3521 01
337
Diagram:
ZCL
Zero Crossing low
ZC
Measured Zero crossing
ZCH
Zero Crossing high
A1
Start point for the torque rate calculation in the torque rate check
A2
End point for the torque rate calculation in the torque rate check
Angle
Torque
A1
Check Zero Crossing
A2
Step x
Step x-1
ZC
ZCL
ZCH
Result var.:
"Zero Cr. A", "Zero Cr. A1", "Zero Cr. A2 " (measured zero crossing)
Alarms:
Zero Crossing high (ZCH), Zero crossing low (ZCL)
Trace
:
ZCH and ZCL are shown in trace as vertical lines. The calculated line is shown as a straight
line, from the end of the step and down to the torque axis. The lines are only shown when
Torque vs. Angle is selected.