Tightening
380
9836 3521 01
Two result variables are produced. "Bolt YP T", which is how much the torque increases
after the yield point, is calculated as
"Bolt YP T" = T
Cycle End
– T
YP
where T
Cycle End
is the Cycle End Torque (as described by Bolt Monitoring).
The second variable, "Bolt YP A" represents how much the angle is increased from the yield
point to the cycle end. It is calculated as:
"Bolt YP A" = A
Cycle End
– A
YP
The function checks that "Bolt YP T" is within the limits
YTH
and
YTL
and that "Bolt YP A" is
within the limits
YAH
and
YAL
. Note that
YTH
and
YTL
can be negative.
All limits, that is,
YTH
,
YTL
,
YAH
and
YAL
, are optional. Leaving them blank disables the
respective check but the values are still calculated and reported.
If
Fatal
is not checked a value outside the specified limits is considered to be a repairable
error. If a value cannot be calculated and at least one limit is specified for the check in
question it is always considered
Fatal
. This is for example the case if the yield points are
not found or if the buffer is empty.