Tightening
326
9836 3521 01
6.5.4.5 Check mean torque
Parameters:
MTH
(Mean torque high),
MTL
(Mean torque Low),
TI
(Time)
Function:
The average torque during the last TI seconds of the step is measured. The calculated
value is checked to be between the high limit MTH and the low limit MTL.
Both limits are optional. Leaving them blank disables the check but the result value is still
calculated and reported.
This check requires that at least one sample is collected after the torque spike elimination
phase. If not, and at least one limit is specified, the steps status is set to
Fatal
and the error
bit of the respective limit is set.
Diagram:
Time
Torque
MTH
Mean Torque High
OSHT
Overshoot time
MTL
Mean Torque Low
TI
Time
Step
TI
Mean Torque
MTL
MTH
OSHT
Shut-off point
Result var.:
"Mean T" (mean torque).
Alarms:
Step mean torque high (MTH) and Step mean torque low (MTL).
Trace
:
There are no limits in trace for this check.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...