Basic Functions
98
9836 3521 01
Choose
1/0
(OK=1)
to have an OK result, that is, OK and OKR, reported with value 1 (one) and a
NOK result, that is, NOK, NOKRM, and TERMNOK, reported with value 0 (zero).
Choose
0/1
ASCII (OK=0)
to have the status using ASCII digits. An OK result is then reported as
the digit "0" (0x30) while a NOK result is reported as the digit "1" (0x31).
For all TC based devices you can control the order in which the step results are printed. This is done using
the
Order steps by
combo box on the Step data tab. Select
Execution order
to print the steps in the
order that they are executed and
Step number
to have them ordered in ascending step number order.
3.7.4.3 Cycle Data layout example
Standard layout
Configuring a reporter of type Printer with
Type of layout
set to "Standard",
Additional new lines
to 1
and the following result variables:
Station variables:
Variable
Width
No Of
Decimals
Text
Station
8
Yes
Time
24
Yes
Status
9
Yes
<New Line>
Bolt variables:
Variable
Width
No Of
Decimals
Text
Bolt No
8
Yes
Bolt T
7
1
Yes
Bolt A
7
Yes
Status
7
Yes
<New Line>
Step variables:
Variable
Width
No Of
Decimals
Text
Step
Numbers
Step No
8
yes
Peak T
7
1
yes
A
3
yes
<New Line>
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...