System Architecture
9836 3521 01
29
Item
Function
Use
Ethernet
Ethernet interfaces
For communication with other TCs. In System TC:s the
second Ethernet interface is used for communication
with the Consol Computer (ToolsTalk PowerMACS),
100 MBits
CPU
Central Processing Unit
PowerPC 880, 120 MHz
RAM
Random Access Memory
For storage of program and data when executing, 32
MB
Flash-PROM
Programmable Read Only
Memory of Flash type
For storage of boot and application software.
SRAM
Static RAM with battery
backup
For storage of set-ups, traces, cycle data etc.
2 MB
ST bus
St bus (2 ch)
ST bus 1 is for communication with the drive and the
spindle, located in the tool connector. ST bus 2 is for
communication with ST based accessories.
Emerg. stop
Emergency Stop
Class 3 Emergency Stop, breaks the gate drive
voltage.
Local DI
Digital input
Opto Isolated Digital Input
Local DO
Digital Output
Relay Outputs
Serial
Serial interface
Interface to serial devices, 3 channels RS232, 1
channel RS422, 2 channels RS485
MACS I/O
CAN bus interface
Opto Isolated interface to MACS I/O and other
accesories
AnyBus
FieldBus interfaces
Interface to superior devices
Battery
RAM-backup
Expected life length >10 years
RTC
Real Time Clock
Battery backed Real Time Clock
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...