Set Up and Maintenance
9836 3521 01
131
4.4.2.1 TC node
The TC node represent a TC in the system.
For each TC it is possible to change name and select which monitoring buffer to use for the TC HMI:s
Torque and Angle values.
By default the internal and external Ethernet ports are configured from the TC front panel. If
Configure
external eth
is checked the external Ethernet port will be configured based upon the
IP Address
,
Net
mask
and
Gateway
provided here.
Note 1: A setup with
Configure external eth
checked can only be downloaded to one specific TC in a
network. If
downloaded to several TC‟s all will get the same external IP address, which will lead to an
address conflict in the network.
Note 2: There can only be one gateway specified in a TC. If a correct
Gateway
is specified (not 0.0.0.0)
the internal Ethernet gateway will be disabled (set to 0.0.0.0).
Under each TC all devices connected to it are displayed as leafs. Normally all TCs have a Spindle device.
To the right of each TC it says which station the TC is running under and whether it is a Station TC
(indicated by an asterix as prefix to the station name).
In addition to the spindle device you might add devices as you need them. The PowerMACS system
supports numerous types of devices. To add a device to TC first select the TC to which you want to add a
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...