Appendix
628
9836 3521 01
Code
Comp
Code
Type
Severity Event string
735
71
Setup
Error
Step %d, Control: Incorrect Angle
736
72
Setup
Error
Step %d, Control: Incorrect Time
737
73
Setup
Error
Step %d, Control: Incorrect Current
739
75
Setup
Error
Step %d, Control: Incorrect Percent
740
76
Setup
Error
Step %d, Control: Incorrect No degrees
741
77
Setup
Error
Step %d, Control: Incorrect No of points (NNOS or RNOS)
742
78
Setup
Error
Step %d, Control: Incorrect Increment
743
79
Setup
Error
Step %d, Control: Incorrect Direction
744
80
Setup
Error
Step %d, Control: Incorrect Stop Condition
745
81
Setup
Error
Step %d, Control: Incorrect Digital Input
746
82
Setup
Error
Step %d, Control: Incorrect Digital Output
747
83
Setup
Error
Step %d, Control: Incorrect Step type from PLC
748
84
Setup
Error
Step %d, Restriction: Incorrect FS Angle
749
85
Setup
Error
Step %d, Restriction: Incorrect FS Torque
750
86
Setup
Error
Step %d, Restriction: Incorrect FS Time
752
88
Setup
Error
Step %d, Restriction: Incorrect Cross thread and gradient
753
89
Setup
Error
Step %d, Restriction: Incorrect Torque profile
754
90
Check
Error
Step %d, Check: Peak torque. %f > %f
755
91
Check
Error
Step %d, Check: Torque in angle window. %f > %f
756
92
Check
Error
Step %d, Check: Torque in time window. %f > %f
757
93
Check
Error
Step %d, Check: Mean torque. %f > %f
758
94
Check
Error
Step %d, Check: Angle. %f > %f
759
95
Check
Error
Step %d, Check: Time. %f > %f
760
96
Check
Error
Step %d, Check: Current as Torque. %f > %f
762
98
Check
Error
Step %d, Check: T/T3. %f > %f
763
99
Check
Error
Step %d, Check: Post view torque high.
764
100
Check
Error
Step %d, Check: Post view torque low.
765
101
Check
Error
Step %d, Diagnostic: Static Zero Offset high on T1. abs(%f) > %f
766
102
Check
Error
Step %d, Diagnostic: Dynamic Zero Offset high on T1. abs(%f) >
%f
767
103
Check
Error
Step %d, Diagnostic: Flying Zero Offset high on T1. abs(%f) >
%f
768
104
Check
Warning
Step %d, Diagnostic: Flying Zero Offset high warning on T1.
abs(%f) > %f
769
105
Check
Error
Step %d, Diagnostic: Angle count high on A1. %f > %f
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...