Peripheral Devices
9836 3521 01
615
8.17.5.4 Program, General data
Syntax:
Program[
<pgm name>
].General.
<parameter>
<
pgm name
>
= The name of the program
<parameter>
= See table below
description)
<parameter>
Data type
Description
StopMonAtNokStep
Boolean
If True then monitoring is stopped when a step have a
NOK status when it ends.
Use2ndMonBuf
Boolean
If true then 2nd monitoring buffer is used if there is more
than one used torque or angle channel.
ReportTqLimit
Float
Report threshold torque limit.
If none of the bolts executed for a cycle (disconnected
bolts excluded) exceeded this value then the
corresponding cycle data will be automatically dropped
RemFastTqLimit
Float
Remove fastener torque limit.
When the measured torque exceeds the entered value
the current step is immediately stopped.
Example:
Program[Pgm01].General.StopMonAtNokStep