Astart is defined as the angle where
Tstart
is reached for the first time when monitoring is
running and values are added to the buffer. If
Tstart
is empty Astart is the cycle angle when
monitoring is started (hence it is possible to measure negative angles).
Astop is defined as the angle where torque decreases below
Tstop
(Astop
2
in the picture)
during the overshoot time
. When torque exceeds
Tstop
, Astop is always reset to an
undefined value and a new Astop has to be found for the check to evaluate correctly. An
AStop found is valid as long as the torque does not exceed
Tstop
later during the cycle.
Found positions are erased and reset if the buffer is cleared passed the found positions
(when a step is run in backward direction).
If both
Tstart
and
Tstop
are empty the angle will be measured from monitoring start to
monitoring end. That is, Astart is defined as the cycle angle when monitoring is started and
Astop is the last measured cycle angle while monitoring is running (Aend
2
in the picture).
Astop is measured during all steps except for the SR step.
Both limits, that is,
AH
and
AL
, are optional. Leaving them blank disables the check but the
result values are still calculated and reported.
If
Fatal
is not checked a value outside the specified limits is considered to be a repairable
error. If a value cannot be calculated and at least one limit is specified the check is always
considered
Fatal
. This is for example the case if Astart or Astop are not found or if the
buffer is empty.
Monitoring buffer
selects which monitoring buffer the check should use.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...