Set Up and Maintenance
9836 3521 01
139
The Multiple identifier function can be monitored and controlled from the PowerMACS PLC using its
Multiple identifier variables.
Multiple identifiers are defined in two steps using
Identifier types
and
Result
variables
.
Identifier types
An
Identifier type
is a string supplied by an identifier
Source
, that is, a device that supplies the identifier
data, and fulfills an optional
match condition
.
Any of the systems ID devices but the one configured for the Work piece identifier function can be used as
Source
. In addition to
the ID devices, the six PLC outputs PLCx_IDTYPE_STR (see chapter: Multiple
identifier variables) can be used. These make it possible to supply identification data from other device
types, for example fieldbus, API, etc.
It is not possible to use an id device or the six PLC outputs PLCx_IDTYPE_STR together with an
AudiXML device. If the station has an AudiXML device attatched, possible input sources for the identifier
types will instead consist of AudiXML identifier tags TNR, PRT, PI1, PI2, STC and WID.
The
match condition
is specified using the
Length
parameter and the combination of the
Significant
position
and
Significant string
parameters. For a string to match it must fulfill all the following rules:
If a
Length
is specified then the incoming string must have exactly
Length
characters to pass.
Leave empty to accept strings of any length.
If
Significant position
and
Significant string
are non-empty then the specified character position
are first picked out from the incoming string. These must then match the regular expression
specified by the significant string (see chapter: Conversion table for a description of regular
expressions). Leave empty to accept all strings regardless of their content.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...