Tightening
9836 3521 01
309
6.5.3.2 Fail Safe Time
Parameters
: Time
Function
:
Supervises the fail-safe limits for Time, The fail safe limits are active also during the step
overshoot time.
Time measurement starts at step start (after start delay for step) and end when the step has
ended and post step check time has elapsed. The measured time must be less than the fail-
safe time limit.
Diagram
:
See Fail Safe Torque
Alarms
:
Time restriction (TIR)
Trace
:
Fail safe limits parameters must be enabled in the trace form (see View of trace curves).