Tightening
290
9836 3521 01
6.5.2.13 TD - Run until Torque has decreased
Step type Id:
10
Parameters:
T (Torque), A (Angle), DIR (Direction)
Function
:
Run spindle, in DIR direction, until angle A is reached. The rotation continues but from that
point the torque is measured. The step stops when the measured torque is less than, or
equal to, T.
Diagram
:
Angle
Torque
A
Angle
T
Torque
Step
A
T
Trace
:
Torque T is shown as a horizontal line from step start to step stop in trace when Torque vs.
Time is selected. Control parameters must be enabled in the trace form (see
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...