Page 1: ...XPower Powerpack 400 and 400 PLUS Owner s Guide ...

Page 2: ...tive owners and are used herein for identification purposes only Notice of Copyright Xpower Powerpack 400 and 400 Plus Owner s Guide April 2003 Xantrex International All rights reserved Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING XANTREX TECHNOLOGY INC XANTREX a MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR ...

Page 3: ... The Guide provides safety guidelines detailed planning and setup information as well as information about operating and troubleshooting the unit Conventions Used The following conventions are used in this guide WARNING Warnings identify conditions that could result in personal injury or loss of life CAUTION Cautions identify conditions or practices that could result in damage to the product or to...

Page 4: ...tion is specific to one model then reference is made specifically to the XPower Powerpack 400 or to the XPower Powerpack 400 Plus Related Information You can find more information about Xantrex Technology Inc as well as its products and services at www xantrex com Important These notes describe an important action item or an item that you must pay attention to Note These notes describe additional ...

Page 5: ...d XPower Powerpack 400 Plus be sure to read and save these safety instructions WARNING Shock hazard Keep Away from Children The XPower Powerpack 400 and XPower Powerpack 400 Plus generates the same potentially lethal AC power as a normal household wall outlet Do not insert foreign objects into the AC Outlet the DC Power Socket the Jump Start Cable Port or the ventilation holes Do not expose this p...

Page 6: ...sion hazard Do not use this product where there are flammable fumes or gases such as in the bilge of a gasoline powered boat or near propane tanks Do not use this product in an enclosure containing automotive type lead acid batteries These batteries unlike the sealed AGM battery in XPower Powerpack 400 and XPower Powerpack 400 Plus vent explosive hydrogen gas which can be ignited by sparks from el...

Page 7: ...t cables red and black clamps to touch each other or another common metal conductor This could cause damage to the unit and or create a sparking explosion hazard Always disconnect the jump start cables from the unit after use and clip the plastic guard over the jump start cable port WARNING Fire hazard Jump start cable clamps must be connected positive to positive red clamp to battery and negative...

Page 8: ...rminals exposed at the Jump Start Cable Port have enough energy present to cause a spark creating an explosion hazard or to cause burns if a metal object contacts both terminals Always clip the plastic guard over the Port when not in use WARNING Fire Hazard XPower Powerpack 400 Plus Do not leave the compressor unattended while operating The compressor is designed for short term operation only Oper...

Page 9: ...ts and cause an explosion 5 Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A lead acid battery produces a short circuit current high enough to weld a ring or other similar objects to metal causing a severe burn 6 If you need to remove a battery always remove the positive terminal from the battery first Make sure all accessories are o...

Page 10: ...wash immediately with soap and water If acid enters your eyes immediately flood them with running cold water for at least twenty minutes and get medical attention immediately 11 Keep a supply of baking soda on hand in the area of the batteries Baking soda neutralizes lead acid battery electrolyte ...

Page 11: ... Powerpack 400 Plus Small battery operated appliances like flashlights razors and night lights that can be plugged directly into an AC receptacle to recharge Some chargers for battery packs used in hand power tools These affected chargers display a warning label stating that dangerous voltages are present at the battery terminals CAUTION The output of the inverter is non sinusoidal Note If you are...

Page 12: ...x ...

Page 13: ...ntroduction About the XPower Powerpack 1 1 Comprehensive Protection 1 1 Automatic overload 1 1 Overheating 1 1 Low Battery Protection 1 2 Jump Start Cables Safety Feature 1 2 2 Features Materials List 2 1 XPower Powerpack Features 2 2 Front Panel Detail 2 2 Air Compressor XPower Powerpack 400 Plus only 2 5 Left Side View 2 6 Storage Compartment 2 7 Accessories 2 8 ...

Page 14: ...e 3 7 Operating 12 V DC Appliances 3 8 Jump Starting a Vehicle s Engine 3 10 Using the Air Compressor XPower Powerpack 400 Plus 3 12 Over Temperature Safety Protection 3 13 Inflating Tires 3 14 Inflating Small Sports Equipment 3 15 Connecting to an External Battery 3 17 4 Maintenance Battery Maintenance 4 1 Recharging the XPower Powerpack Battery 4 2 Recharging with the AC Charger 4 3 Recharging w...

Page 15: ...ng Common Problems 5 1 Buzz in Audio Equipment 5 1 Television Interference 5 1 Troubleshooting Reference 5 2 A Specifications Electrical Specifications A 1 Physical Specifications A 3 B Warranty and Product Information Warranty B 2 Return Material Authorization Policy B 5 Out of Warranty Service B 7 Information About Your System B 8 ...

Page 16: ...xiv ...

Page 17: ...ncy use In addition the XPower Powerpack 400 Plus Comes with a 250 psi air compressor for inflating tires and small sports equipment Comprehensive Protection Automatic overload The XPower Powerpack has built in protection against output overload If you connect to the AC Outlet s an appliance that draws more than 320 W or one which draws excessive surge power the power to the AC Outlet automaticall...

Page 18: ...he AC Outlet On Off switch is turned on an audible alarm alerts you when the internal battery is nearly discharged 11 0 V DC and the unit turns off at 10 5 V DC Jump Start Cables Safety Feature The XPower Powerpack comes with a user replaceable 250 A fuse to protect the unit and vehicle battery from damage through reverse polarity and short circuit conditions ...

Page 19: ...ck package includes these items XPower Powerpack 400 or XPower Powerpack 400 Plus Owner s Guide AC Charger DC Charging Cable Jump Start Cables Accessory bag The XPower Powerpack 400 Plus also includes two nozzle adaptors for the compressor One sports needle adaptor for the compressor If any of these materials are missing or are unsatisfactory in any way please contact Customer Service see Appendix...

Page 20: ...e appliances Recharge XPower Powerpack from a 12 V outlet in a vehicle using the DC Charging Cable 2 2 AC Outlets are standard 3 prong outlets supplying 120 V AC power for running an AC appliance 3 AC Outlet ON OFF switch illuminates when the switch is turned on 4 Digital Display displays the inverter s Output Power in W and Battery Charge status in FULL 2 3 1 7 5 6 4 8 ...

Page 21: ...ggles Digital Display s power ON OFF Not shown Audible Alarm inside the unit sounds in the event of overheating or low battery protection on inverter How to Required Condition Required Action Note Monitor total AC power consumed by the applications powered from the Powerpack s 2 AC outlets Inverter s ON OFF switch is turned ON Output Power W light illuminates green AC charger is unplugged from the...

Page 22: ... plug in and forget charging method We recommend leaving the AC charger connected when the Powerpack is not in use to permanently maintain the battery in fully charged condition Check Battery Charge status Inverter s ON OFF switch is turned to OFF All appliances must be disconnected from the AC and DC power outlets The ON OFF switch of the incandescent light must be turned to OFF The AC charger mu...

Page 23: ...sor XPower Powerpack 400 Plus only Feature Description 1 On Off switch turns the compressor unit on and off 2 Pressure gauge shows the PSI lb in2 3 Valve connector with connector hose Nozzle Adaptor Compartment is integrated into AC charger compartment 1 2 3 ...

Page 24: ...Start Cable Port supplies high power DC current The cables connect to the Jump Start Cable Port when jump starting a vehicle s battery or when connecting an external battery to the XPower Powerpack The jump start cable connection is designed so that the cables cannot be inserted incorrectly into the Jump Start Cable Port 4 Plastic Guard for covering jump start cable port 2 3 1 3 4 ...

Page 25: ...C wall outlet and can only be used to recharge the internal battery of the XPower Powerpack Can be stored in AC charger compartment 2 Charger Input Socket for use with the AC Charger supplied see 1 3 External Replaceable Fuse is rated at 250 A 32 V Located behind fuse cover 4 Compressor Nozzle Adaptor Compartment 5 AC Charger Compartment may be used for storing the AC Charger 2 3 4 1 5 ...

Page 26: ... Cable lets you recharge the XPower Powerpack from a 12 V system in a car SUV RV or a boat This can be stored in the storage compartment 3 Accessory bag Not Shown Nozzle packet XPower Powerpack 400 Plus only contains 2 nozzle adaptors and sports needle adaptor in the storage compartment on the back of the unit 3 1 2 ...

Page 27: ...onnecting to an external battery for additional run time Using the compressor on the XPower Powerpack 400 Plus Operating Conditions and Guidelines CAUTION Read all operating instructions before operating the XPower Powerpack CAUTION Do not use the XPower Powerpack to operate any AC appliances or 12 V DC appliances while recharging with the AC Charger The AC Charger may fail if AC appliances or 12 ...

Page 28: ...re ignition protected equipment Dry Do not allow water or other liquids to drop or splash on the XPower Powerpack Cool Ambient air temperature should be between 32 and 104ºF 0 and 40ºC the cooler the better within this range Ventilated Leave at least 2 5 cm clearance around the XPower Powerpack for air flow Ensure that the ventilation openings are not obstructed Safe Do not operate the unit in the...

Page 29: ... outlet 4 Insert the AC Charger cable end into the Charger Input Socket located in the storage compartment of the unit The green Charging Status light changes from flashing to steady when charging is complete about 35 hours if the battery is completely discharged Important Prior to operating your AC appliance or 12 V DC appliance ensure that the battery of the XPower Powerpack is fully charged If ...

Page 30: ... rating 320 W 2 7 A Important The 35 hour charging time for the XPower Powerpack assumes that there is 120 V at the AC wall outlet If the voltage is less than 120 V AC it may take more than 35 hours to fully recharge the XPower Powerpack If after 35 hours of charging the green Charging Status light is still flashing continue to charge the unit for another 15 hours Important If you keep the XPower ...

Page 31: ...n Table 3 1 Note The fewer watts an AC appliance uses the longer the XPower Powerpack will operate before recharging is required Table 3 1 AC Appliances and Run Times AC Appliance Wattsa a Represents actual power consumption as measured on sample appliances Hoursb b Operating times assume a fully charged 20 Ah battery and may vary based on model brand of appliance Cordless telephone stand by 5 40 ...

Page 32: ... including the types listed below may be damaged if they are connected to the inverter Electronics that modulate RF radio frequency signals on the AC line will not work and may be damaged Speed controllers found in some fans power tools kitchen appliances and other loads may be damaged Some chargers for small rechargeable batteries can be damaged See Precautions for Using Rechargeable Appliances o...

Page 33: ...e covering on the right side of the XPower Powerpack Turn the AC Outlet On Off switch to the On position The switch illuminates to indicate AC power is available at the AC Outlets 2 Plug the AC appliance into one of the AC Outlets and turn the appliance on XPower Powerpack will operate most devices rated up to 320 W 3 Recharge the XPower Powerpack as soon as possible after each use When using the ...

Page 34: ...ff when the internal battery is discharged To protect the internal battery against damage resulting from total discharge We recommend that the AC Outlet On Off switch is turned On when using the XPower Powerpack to operate a 12 V DC appliance Having the AC Outlet On Off switch turned On enables the alarm to warn you when the 12 V DC appliance has nearly depleted the internal battery Note The fewer...

Page 35: ...iance and the internal circuit breaker automatically resets after a few seconds 3 Fully recharge the XPower Powerpack as soon as possible after each use As the DC power socket is internally wired directly to the internal battery extended operation of a 12 V DC appliance may result in excessive battery discharge See Caution for Equipment damage on page 3 8 Table 3 2 12 V DC Appliances and Run Times...

Page 36: ...clip the plastic guard over the jump start cable port WARNING Fire hazard Jump start cable clamps connection to the vehicle s battery terminals must be positive to positive red clamp to battery and negative to negative black clamp to battery A reverse polarity connection positive to negative may cause damage to the unit and or create a sparking explosion hazard WARNING Risk of explosion fire or bu...

Page 37: ...the engine 6 Connect the red positive clip of the cables to the positive terminal of the engine battery The battery s positive terminal is usually larger in diameter than the negative terminal In most vehicles the battery s positive terminal has a red wire connected to it 7 Connect the black negative clip of the cables to the engine block cylinder head or other stationary heavy metal part of the m...

Page 38: ...re for more than 4 seconds may cause damage to the unit Allow the XPower Powerpack to cool down for at least 3 minutes after each jump start Important Recharge the XPower Powerpack as soon as possible after each use See Recharging the XPower Powerpack Battery on page 4 2 WARNING Fire Hazard The compressor is designed for short term operation only Operating the compressor over an extended period of...

Page 39: ...ng temperature it will automatically turn on again and continue inflating You should turn the compressor off at the power switch if this safety feature engages and allow the compressor to cool for 15 minutes before re starting WARNING Fire Hazard Do not leave the compressor unattended while in operation Keep out of reach of children WARNING Risk of personal injury or damage to equipment Never leav...

Page 40: ...ting when its internal temperature drops Turn the compressor off at the power switch after each use or any time the compressor turns off automatically Tires PSI Other Inflatables PSI 520 13 26 Football 13 A 78 14 26 Basketball 9 E78 14 30 Volleyball 5 H 78 14 24 Lawn Tractor Tire 22 HR 78 15 28 Bicycle Tires 27 1 85 20 1 40 Note The information in the table is for reference only For precise pressu...

Page 41: ...ed 4 Open the thumb latch and remove the valve connector from the valve stem 5 Check air pressure with a pressure gauge Inflating Small Sports Equipment You can use the compressor to inflate small sports equipment such as balls soccer balls and footballs CAUTION If the pressure gauge on the compressor indicates more than twice the recommended pressure for the object you are inflating and you have ...

Page 42: ...opriate pressure 5 Turn the compressor off before removing nozzle adaptor from valve stem 6 Remove nozzle adaptor from valve connector and store in storage compartment CAUTION The XPower Powerpack cannot be used to inflate large capacity inflatables such as float tubes large air mattresses and inflatable boats These types of products require extended inflating times which may damage the compressor...

Page 43: ...p start cables red and black clamps to touch each other or another common metal conductor This could cause damage to the unit and or create a sparking explosion hazard Always disconnect the jump start cables from the unit after use and clip the plastic guard over the jump start cable port WARNING Fire hazard Jump start cable clamps must be connected positive to positive red clamp to battery and ne...

Page 44: ...e external battery when the external battery is discharged or no longer needed remove the red positive clip and then remove the black negative clip 2 Remove the cables from the Jump Start Cable Port WARNING Acid spills Use a sealed non spillable battery for indoor use Common auto and marine batteries are not suitable for indoor use unless their fumes are vented outdoors Common auto and marine batt...

Page 45: ... an External Battery 975 0057 01 01 3 19 3 Recharge the XPower Powerpack as soon as possible after use CAUTION Do not recharge the XPower Powerpack when an external battery is connected The AC charger may be damaged ...

Page 46: ...3 20 ...

Page 47: ...nce All rechargeable batteries gradually discharge when left standing and you need to recharge them periodically to maintain maximum battery capacity The AC Charger supplied with the XPower Powerpack is designed to regulate the charging process ensuring that the battery is always fully charged but never overcharged To ensure safe recharging and maximum battery life recharge the XPower Powerpack on...

Page 48: ...CAUTION Due to inherent self discharge lead acid batteries must be charged at least every 3 months especially in a warm environment Leaving a battery in a discharged state or not recharging every 3 months may result in permanent battery damage and poor jump start performance CAUTION Do not attempt to recharge the XPower Powerpack battery if it is frozen Gradually warm the frozen battery to 32 F 0 ...

Page 49: ... completely discharged a typical recharge may take up to 35 hours When fully charged the green Charging Status light changes to steady and the XPower Powerpack is ready to use CAUTION Do not operate AC or DC appliances while the XPower Powerpack is being recharged with the AC Charger The AC Charger may be permanently damaged if AC appliances or 12 V DC appliances are operated while the AC Charger ...

Page 50: ...rged while you drive your vehicle Important Although the charge regulation circuitry in the XPower Powerpack does not operate with this charging method most vehicle voltage regulators will ensure that the XPower Powerpack is not overcharged WARNING Fire and Explosion Hazard Do not use this recharging method if your vehicle has abnormally high voltage electrical systems that operate above 15 V DC T...

Page 51: ...ed or if your vehicle s engine is not running disconnect the DC Charging Cable from both sockets Most of the XPower Powerpack s capacity will be restored in four hours while the vehicle engine is running Note The green Charging Status light will not illuminate when the XPower Powerpack is recharged through the DC Charging Cable Note Battery Charge indicator is only accurate when the XPower Powerpa...

Page 52: ...ost generators are equipped with them Use this power source for faster charging Using a generator with a regulated 12 V DC lighter socket Follow the connection instructions in Recharging with the DC Charging Cable on page 4 4 Most of the XPower Powerpack s battery capacity will be recharged in a few hours WARNING Fire and Explosion Hazard The generator output must be intended for battery charging ...

Page 53: ...ctor is inserted into the Charger Input Socket and the solar panel is placed in the sun the XPower Powerpack charges automatically just as with the AC Charger See Recharging with the AC Charger on page 4 3 It takes about ten hours in direct sunlight to recharge the XPower Powerpack from a 2 5 A solar panel Replacing the Internal Battery Battery Life The high quality battery used in the XPower Powe...

Page 54: ...ery CAUTION Discharging the internal battery below 10 0 V will damage the battery and shorten its life Table 4 1 Approved Replacement Batteries Replacement Battery Where to Buy Panasonic LC X1220P 12 V 20 Ah Panasonic Tel 1 800 833 9626 web www pasc panasonic com Digi Key Tel 1 800 344 4539 EnerSys NPX 80 12 V 20 Ah EnerSys Tel 1 800 962 1287 Eastern US Tel 1 800 423 4667 Western US web www Enersy...

Page 55: ...ce the battery 1 Place the XPower Powerpack upright on a stable level surface 2 On the XPower Powerpack unscrew the four fasteners on the battery cover Place the fasteners in the cover for safe keeping WARNING If you do not know how to safely remove and install batteries have this task performed by a qualified service technician WARNING Fire hazard When installing the replacement battery make sure...

Page 56: ...attery terminal is next to the red positive internal cable and the black negative terminal is next to the black negative internal cable 5 Securely fasten the bolt and washer that holds the red positive cable to the positive battery terminal and the black negative cable to the negative battery terminal 6 Do not overtighten the bolt Consult the battery manufacturer for torque specifications Fastener...

Page 57: ...nscrew the black knob at the back of the assembly 5 Remove the old bulb and insert a replacement bulb of the same type and rating into the light reflector assembly 6 Holding the light reflector assembly gently screw the black knob on to the back of the assembly 7 Reattach the lens and cover Replacing the External Fuse The replacement fuse must be rated at 250 A 32 V DC See page 2 7 for a diagram T...

Page 58: ...4 12 ...

Page 59: ...htly when powered by the XPower Powerpack The best solution to eliminate the buzzing is to use an audio system with a good quality filter Television Interference The XPower Powerpack is shielded to minimize interference with TV signals If TV signals are weak you may see interference in the form of lines scrolling across the TV screen Try one of the following suggestions to minimize or eliminate th...

Page 60: ...leshooting reference Problem Possible Cause Solution AC appliance will not operate audible alarm is not sounding AC appliance rated more than 320 W the safety overload has tripped AC appliance is rated less than 320 W high starting surge has tripped the safety overload Use an AC appliance with a power rating less than 320 W AC appliance may exceed the XPower Powerpack s surge capability Use an AC ...

Page 61: ...or ventilation or excessively warm environmental conditions Turn off the AC Outlet On Off switch and let the XPower Powerpack cool down Alarm sounds Internal battery is nearly discharged 11 0 V If you ignore this warning the XPower Powerpack automaticallyswitches off when the battery reaches 10 5 V Turn the AC outlet ON OFF switch OFF and recharge the XPower Powerpack Run time is less than expecte...

Page 62: ...nnected from all appliances and all charging sources for fifteen minutes Charging Status light is Off when AC Charger is connected No AC power at the AC wall outlet AC Charger is faulty Ensure power is available at the AC wall outlet Replace the AC Charger Green Charging Status light is flashing indicating recharging and Battery Charge does not turn on Battery Charge reading on digital display is ...

Page 63: ...ced on the valve stem The item being inflated may have a leak Check that the valve connector is securely placed on the valve stem before closing the thumb latch Check that the item being inflated has no leaks Check the compressor hose for any breaks or leaks at connections The compressor runs slowly XPower Powerpack 400 Plus only The compressor may have overheated from excessive use Battery voltag...

Page 64: ...ability Recharge the XPower Powerpack battery Have the engine serviced Replace 250 A 32 V fuse with same type and ratings The battery clamps of the jump start cablesmeasure zero volts External fuse 250 A is blown Replace 250 A 32 V fuse with same type and ratings The light does not turn on Light bulb has burnt out Remove lens cover and replace bulb with one of the same type and rating Table 5 1 Tr...

Page 65: ...lead acid Internal battery voltage nominal 12 V DC Internal battery capacity minimum 20 Ah Internal battery CCA rating 200 CCA DC Power Socket maximum continuous load 12 A with automatic reset Built in incandescent light replaceable 5 W bulb Jump start cable port 50 A Jump start fuse external user replaceable 250 A ...

Page 66: ...V DC High battery voltage shutdown Yes automatic reset Over temperature shutdown Yes automatic reset Overload shutdown Yes automatic reset AC output short circuit protection Yes automatic reset Fuse internal 2 x 25 A or 1 x 50 A Operating temperature range 32 104 ºF 0 40 ºC Storage temperature range 32 86ºF 0 30 ºC Internal Battery Charging Controller System AC Charger bulk charging current 750 mA...

Page 67: ...m 18 AWG with male to male lighter plugs AC Charger input 120 10 V AC 60 Hz Nozzle adaptor for air compressor on the XPower Powerpack 400 Plus only two nozzle adaptors one sports needle adaptor Physical specifications XPower Powerpack 400 XPower Powerpack 400 Plus Depth 8 20 3 cm 8 20 3 cm Width 16 40 6 cm 16 40 8 cm Height 9 24 1 cm 9 24 1 cm Weight 21 8 lb 9 9 kg 23 lb 10 5 kg Important All spec...

Page 68: ...A 4 ...

Page 69: ...y for your XPower Powerpack 400 and XPower Powerpack 400 Plus as well as instructions for returning the product for servicing Appendix B also has a form where you can record information Information About Your System on page B 8 in case you need to contact Customer Service ...

Page 70: ...s Xantrex reserves the right to use parts or products of original or improved design in the repair or replacement If Xantrex repairs or replaces a product its warranty continues for the remaining portion of the original Warranty Period or 90 days from the date of the return shipment to the customer whichever is greater All replaced products and all parts removed from repaired products become the p...

Page 71: ...Warranty does not cover normal wear and tear of the product or costs related to the removal installation or troubleshooting of the customer s electrical systems This warranty does not apply to and Xantrex will not be responsible for any defect in or damage to a the product if it has been misused neglected improperly installed physically damaged or altered either internally or externally or damaged...

Page 72: ...OR ANY SPECIAL DIRECT INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSSES COSTS OR EXPENSES HOWEVER ARISING WHETHER IN CONTRACT OR TORT INCLUDING WITHOUT RESTRICTION ANY ECONOMIC LOSSES OF ANY KIND ANY LOSS OR DAMAGE TO PROPERTY ANY PERSONAL INJURY ANY DAMAGE OR INJURY ARISING FROM OR AS A RESULT OF MISUSE OR ABUSE OR THE INCORRECT INSTALLATION INTEGRATION OR OPERATION OF THE PRODUCT Exclusions If...

Page 73: ...presentation in connection with any use of the product for such purposes Return Material Authorization Policy Before returning a product directly to Xantrex you must obtain a Return Material Authorization RMA number and the correct factory Ship To address Products must also be shipped prepaid Product shipments will be refused and returned at your expense if they are unauthorized returned without a...

Page 74: ... telephone number where you can be reached during work hours A brief description of the problem 3 Ship the unit prepaid to the address provided by your Xantrex customer service representative If you are returning a product from outside of the USA or Canada In addition to the above you MUST include return freight funds and are fully responsible for all documents duties tariffs and deposits If you a...

Page 75: ...er Powerpack 400 and XPower Powerpack 400 Plus for out of warranty service contact Xantrex Customer Service for a Return Material Authorization RMA number and follow the other steps outlined in Return Procedure on page B 6 Payment options such as credit card or money order will be explained by the Customer Service Representative In cases where the minimum flat fee does not apply as with incomplete...

Page 76: ...atives give you better service Serial Number on DC end _______________________________ Purchased From _______________________________ Purchase Date _______________________________ Type of installation e g RV truck vehicle home ______________________________ Warning Error or Panel Fault Message ______________________________ Appliances operating when problem occurred ______________________________ ...