Operation
3-2
975-0057-01-01
Choosing a Location
The
XPower Powerpack
should be operated only in a location
that meets these requirements:
:
CAUTION
The
XPower Powerpack
is not intended for use as
a UPS (Uninterruptible Power Supply).
WARNING: Fire or explosion
The
XPower Powerpack
contains components that
tend to produce arcs or sparks. To prevent fire or
explosion, do not operate the
XPower Powerpack
in compartments containing batteries or flammable
materials, or in locations that require ignition-
protected equipment.
Dry
Do not allow water or other liquids to drop or splash on the
XPower Powerpack
.
Cool
Ambient air temperature should be between 32 and 104ºF
(0 and 40ºC)—the cooler the better within this range.
Ventilated
Leave at least 2" (5 cm) clearance around the
XPower
Powerpack
for air flow. Ensure that the ventilation
openings are not obstructed.
Safe
Do not operate the unit in the same compartment as
batteries or in any compartment capable of storing
flammable liquids like gasoline.
Protected
from battery
gases
Do not operate the unit where it will be exposed to battery
gases. These gases are very corrosive, and prolonged
exposure will damage the
XPower Powerpack
.