Murata Power Solution’s DMS-PS-CM Series 
of high-efficiency, chassis mount AC/DC 
power supplies feature low noise (40mV on 
main, 8mV on auxiliaries), fully-is24, 
+12V, and +5V outputs, making them perfect 
for powering today’s complex instrumenta-
tion. A high-current main output is isolated 
from the AC line by 3000Vac. In dual- and 
triple-output models, the low-current auxiliary 
outputs are isolated from the main output by 
1000Vdc, and from each other by 2000Vdc, 
effectively providing double isolation from the 
AC line! This unprecedented isolation elimi-
nates ground loop problems in complex, 
multiple-instrument applications.

Full-load efficiencies of up to 80% and 

output-power ratings of 5, 10 or 16 Watts, 
combine to ensure minimal ac power con-
sumption. For intermittent use or low-power 
applications, the 5-Watt model’s no-load 
quiescent consumption with a nominal 
120Vac input is a mere 0.6 Watts---that’s 
nearly seven times less than a standard 4W 

night light! These low cost, high-efficiency 
power supplies can significantly reduce 
long-term electricity costs in low (<5Watts) 
to medium (<16Watts) power applications.

All DMS-PSX-CM power supplies fea-

ture universal inputs of 85-264Vac 50/60Hz, 
built-in line fuses, and on-board ‘Power On’ 
LED indicators. At full rated load, hold-up 
time is typically 20ms at 120Vac, and 80ms 
at 230Vac. All outputs provide indefinite 
short-circuit protection and, for added reli-
ability, the main high-current output also 
includes overvoltage protection. A rugged, 
vibration-proof, chassis mount package 
incorporates large, shock-resistant terminal 
blocks for all I/O connections. 

Multiple outputs, low noise, low cost, 

high efficiency, double isolation, and rugged 
construction combine to make DMS-PSX-
CM Series AC/DC power supplies the 
ideal choice for powering today’s sensitive 
instrumentation, and any electronic device 
that requires a reliable dc voltage!

Figure 1. DMS-PS-CM Series Simplified Schematic

or

110-340Vdc

TB4

F1

1A/250V

TB1

LDO

Regulator

DC/DC

Converter

IN

OUT

GND

AC(L)

AC(N)

FG

+

V1

TB2

+

V2

LDO

Regulator

DC/DC

Converter

AC/DC Converter

Drive

Circuitry

(Auxilliary)

(Auxilliary)

(Main)

IN

OUT

GND

TB3

+

V3

+

+

+

+

+

+

+

+

+

**

*

**

**

Used only on dual and triple-output models

*

Not used on single-output models

85-264V
50/60Hz

or

110-340Vdc

+

Figure 1. Simplified Schematic

FEATURES

N

 

Up to 80% efficient single, dual, and triple-
output model

N

 

Individual, fully-isolated outputs: 

3000Vac on main 
4000V double-isolation on auxiliaries

N

 

Available with +5V, +12V, and +24V outputs

N

 

Low noise: 40mVp-pk on main, 8mVp-pk on   
auxiliaries; Ideal for sensitive instrumentation

N

 

Universal input: 85-264Vac @ 47-63Hz or  
110-340Vdc

N

 

Choice of 5, 10, or 16W models for minimal  
system power-consumption

N

 

Standby power consumption as low as 0.6W

N

  Short-circuit protection on all outputs;  

OVP on main output

N

 

Built-in ac mains fuse & ‘Power On’ indicator

N

 

5W models operate up to 5 LED-display DPM’s

N

 

Vibration-resistant, chassis-mount  
modular packages

N

 

EMC compliant; UL/CSA recognized

N

 

Low cost!

DMS-PS-CM Series

High Efficiency, AC/DC Instrumentation Power 

Supplies with Individually Isolated Outputs

MPM_DMS-PS-CM.B02

 

Page 1 of 8

For full details go to

www.murata-ps.com/rohs

www.murata-ps.com

Technical enquiries

 email: [email protected], tel: 

+1 508 339 3000

8

85-

264

Vac

 o

or

 11

0-3

40

0V

dc

Un

iv

e

er

sa

In

p

u

t

FE

AT

UR

ES

OBSOLETE PRODUCT 

Contact Factory for Replacement Model 

Summary of Contents for DMS-PS-CM

Page 1: ...shock resistant terminal blocks for all I O connections Multiple outputs low noise low cost high efficiency double isolation and rugged construction combine to make DMS PSX CM Series AC DC power supplies the ideal choice for powering today s sensitive instrumentation and any electronic device that requires a reliable dc voltage Figure 1 DMS PS CM Series Simplified Schematic or 110 340Vdc TB4 F1 1A 2...

Page 2: ...Nm Rated Voltage 630V VDE 0110 V Group 2 250V VDE 0110 V Group 3 EMI All models Meets CISPR Pub 22 FCC Class B Safety Approvals Pending DC Outputs Line Regulation All outputs 0 1 max Load Regulation V1 All models 2 V2 V3 All models 0 2 max Output Accuracy Max V1 All models 2 0 V2 V3 All models 2 5 Hold UpTime 47 63Hz 115Vac 20mSec typ 230Vac 80mSec typ Noise Ripple All models 20MHz bandwidth See N...

Page 3: ...g and then disconnecting the ac mains from TB4 Next disconnect all load wiring from TB1 TB2 and TB3 Lastly remove the four screws that secure the pc board to the plastic case After making sure that the new fuse is securely attached to its mounting clips re assemble the unit using all four screws Reconnect all input and output wiring and re apply ac power If the unit still does not operate properly...

Page 4: ...ending on model 9 Temperature Derating See Figure 3 All DMS PS CM supplies are speci fied to operate at their full rated power over the temp range of 0 C to 50 C in still air convection cooling without any thermal derating For operation over 50 C in still air derate the output power linearly by 2 5 per C down to 50 rated power at 70 C To operate the units at full rated power between 50 C and 70 C a...

Page 5: ...regard to ground loop problems that may be encountered when powering 800 DPM s from a single power supply Application Information 1 Chassis Mounting Considerations In order to minimize self heating DMS PS CM power supplies should always be mounted in either a vertical or horizontal position Avoid mounting units upside down or in close proximity to other heat generating devices Also be sure to use ...

Page 6: ...MS PS6 CM V1 24V DMS PS9 CM V1 24V DMS PS3 CM V2 4 85V DMS PS6 CM V2 4 85V DMS PS9 CM V2 4 85V DMS PS CM Series High Efficiency AC DC Instrumentation Power Supplies with Individually Isolated Outputs MPM_DMS PS CM B02 Page 6 of 8 Technical enquiries email sales murata ps com tel 1 508 339 3000 www murata ps com ...

Page 7: ... CM V2 4 85V DMS PS9 CM V2 4 85V DMS PS3 CM V1 5V DMS PS6 CM V1 24V DMS PS9 CM V1 24V Typical Performance Curves TA 25 C VIN 120V 60Hz DMS PS CM Series High Efficiency AC DC Instrumentation Power Supplies with Individually Isolated Outputs MPM_DMS PS CM B02 Page 7 of 8 Technical enquiries email sales murata ps com tel 1 508 339 3000 www murata ps com ...

Page 8: ...use or sell equipment constructed in accordance therewith Specifications are subject to change without notice 2008 Murata Power Solutions Inc USA Mansfield MA Tel 508 339 3000 email sales murata ps com Canada Toronto Tel 866 740 1232 email toronto murata ps com UK Milton Keynes Tel 44 0 1908 615232 email mk murata ps com France Montigny Le Bretonneux Tel 33 0 1 34 60 01 01 email france murata ps com...

Reviews: