6F2S1915 (0.46)
GRZ200 (Soft 031 & 032)
- 1466 -
Function table
Function
Block
Protection function
Ordering
No.
§
1
31
32
ZS
(6zones)
21
Distance protection(for phase fault) with 6zones
●
●
68
Power swing block
SOTF-OC
Switch on to fault protection
ZG
(6zones)
21N
Distance protection(for earth fault) with 6zones
●
●
68
Power swing block
SOTF-OC
Switch on to fault protection
DEFCAR
85-67N
Directional earth fault carrier command protection
●
●
DISCAR
85-21
Distance carrier command protection
●
●
OC
50/67
Non-directional / directional definite time over-current protection
●
●
51/67
Non-directional / directional inverse time over-current protection
EF
50N/67N
Non-directional / directional definite time earth fault over-current protection
●
●
51N/67N
Non-directional / directional inverse time earth fault over-current protection
OCN
46/67
Non-Directional / directional Negative sequence phase over-current protection
●
●
THM
49
Thermal overload protection
●
●
BCD
46BC
Broken conductor protection
●
●
CBF
50BF
Circuit breaker failure protection
●
●
STUB OC
50STUB
Stub protection
●
●
OV
59
Phase over-voltage protection
●
●
OVS
59
Phase-phase over-voltage protection
●
●
OVG
59N
Earth fault over-voltage protection
●
●
UV
27
Phase under-voltage protection
●
●
UVS
27
Phase-phase under-voltage protection
●
●
FRQ
81
Frequency protection
●
●
OSTZ
56Z
Out of step tripping by distance
●
●
ICD
ICD
Inrush current detection function
●
●
FS
FS
Fail-safe function
●
●
VTF
VTF
VTF detection function
●
●
CTF
CTF
CTF detection function
●
●
FL-Z
21FL
Fault locator
●
●
ARC
79
Autoreclosing function
●
●
VCHK
25
Voltage check for autoreclosing
●
●
TRC
94
Trip circuit
●
●
CLP
–
Cold load protection function
●
●
General
control
LEDR
LED reset
●
●
GCNT
Counter function for the general
●
●
MDCTRL
Mode control function
●
●
Ctrl and
Monitor
SPOS
Single position device function
●
DPSY
Double position controller with synchronizing
●
SOFTSW
Software switch controller
●
OPTR
Operation time reset
●
TOTALTIM
Total time measurement
●
SYNDIF
Synchronizing check for different network
●
INTERLOCK Software interlock
●
DPOS
Double position device function
●
TPOS
Three position device function
●
GENBI
Event detection function for general BIs
●
ASEQ
Automatic sequence control function
●
Ba
sic
Ba
sic wi
th
con
trol
§
1
Ordering number selected is set at ‘G’ & ‘T’ positions of Software selection (see p. 1465)
.
Содержание GR 200 Series
Страница 1047: ...6F2S1915 0 46 GRZ200 Soft 031 032 1026 Figure 8 3 4 Screen shot from GR TIEMS ...
Страница 1354: ...6F2S1915 0 46 GRZ200 Soft 031 032 1333 Appendix 1 Signal list for common function ...
Страница 1369: ...6F2S1915 0 46 GRZ200 Soft 031 032 1348 Unit mm Panel cut out for 1 2 case size Figure 2 2 3 Panel cutout figure 1 2 size case ...
Страница 1410: ...6F2S1915 0 46 GRZ200 Soft 031 032 1389 This page is intentionally blank ...
Страница 1480: ...6F2S1915 0 46 GRZ200 Soft 031 032 1459 Appendix 6 Ordering ...
Страница 1497: ...6F2S1915 0 46 GRZ200 Soft 031 032 1476 Appendix 7 Technical data ...
Страница 1518: ...6F2S1915 0 46 GRZ200 Soft 031 032 1497 Appendix 8 Manufacture setting ...
Страница 1520: ...6F2S1915 0 46 GRZ200 Soft 031 032 1499 Appendix 9 Matrix between VCT terminals and relay applications ...
Страница 1523: ...6F2S1915 0 46 GRZ200 Soft 031 032 1502 Appendix 10 CT requirement ...
Страница 1531: ...6F2S1915 0 46 GRZ200 Soft 031 032 1510 Appendix 12 Engineering exercise ...
Страница 1563: ......