![Texas Instruments AM1808 Скачать руководство пользователя страница 968](http://html.mh-extra.com/html/texas-instruments/am1808/am1808_technical-reference-manual_1094558968.webp)
UHPI_HCS
UHP_HAS
Internal
UHPI_HRDY
UHPI_HD[15:0
]
UHPI_HR/W
UHPI_HCNTL[1:0]
HHWIL
10
10
01
01
01
1st halfword
2nd halfword
1st halfword
2nd halfword
1st halfword
UHPI_HSTRB
UHPI_HCS
UHPI_HAS
UHPI_HCNTL[1:0
]
UHPI_HR/W
UHPI_HHWIL
Internal
HSTRB
UHPI_HD[15:0
]
UHPI_HRDY
1st halfword
2nd halfword
1st halfword
2nd halfword
11
11
10
10
1st halfword
00 or 10
00 or 10
2nd halfword
Internal
UHPI_HD[15:0]
UHPI_HRDY
UHPI_HHWIL
UHPI_HR/W
UHPI_HCNTL[1:0]
UHPI_HAS
UHPI_HCS
HSTRB
Architecture
968
SPRUH82C – April 2013 – Revised September 2016
Copyright © 2013–2016, Texas Instruments Incorporated
Host Port Interface (HPI)
21.2.6.9.1
UHPI_HRDY Behavior During Multiplexed-Mode Read Operations
shows an HPIC (UHPI_HCNTL[1:0] = 00b) or HPIA (UHPI_HCNTL[1:0] = 10b) read cycle.
Neither an HPIC read cycle nor an HPIA read cycle causes UHPI_HRDY to go high. For this type of
access, the state of UHPI_HHWIL is ignored, so if a dual halfword access is performed, the same register
will be accessed twice.
Figure 21-7. UHPI_HRDY Behavior During an HPIC or HPIA Read Cycle in the Multiplexed Mode
includes an HPID read cycle without autoincrementing. The host writes the memory address
during the HPIA (UHPI_HCNTL[1:0] = 10b) write cycle, and the host reads the data during the HPID
(UHPI_HCNTL[1:0] = 11b) read cycle. UHPI_HRDY goes high for each HPIA halfword access, but
UHPI_HRDY goes high for only the first halfword access in each HPID read cycle.
Figure 21-8. UHPI_HRDY Behavior During a Data Read Operation in the Multiplexed Mode
(Case 1: HPIA Write Cycle Followed by Nonautoincrement HPID Read Cycle)
includes an autoincrement HPID read cycle. The host writes the memory address while
asserting UHPI_HCNTL[1:0] = 10b and reads the data while asserting UHPI_HCNTL[1:0] = 01b. During
the first HPID read cycle, UHPI_HRDY goes high for only the first halfword access, and subsequent HPID
read cycles do not cause UHPI_HRDY to go high.
Figure 21-9. UHPI_HRDY Behavior During a Data Read Operation in the Multiplexed Mode
(Case 2: HPIA Write Cycle Followed by Autoincrement HPID Read Cycles)