![Texas Instruments AM1808 Скачать руководство пользователя страница 539](http://html.mh-extra.com/html/texas-instruments/am1808/am1808_technical-reference-manual_1094558539.webp)
Applications to Power Topologies
539
SPRUH82C – April 2013 – Revised September 2016
Copyright © 2013–2016, Texas Instruments Incorporated
Enhanced High-Resolution Pulse-Width Modulator (eHRPWM)
Table 16-42. EPWM1 Initialization for Figure 16-57
Register
Bit
Value
Comments
TBPRD
TBPRD
800 (320h)
Period = 1600 TBCLK counts
TBPHS
TBPHS
0
Clear Phase Register to 0
TBCTL
CTRMODE
TB_UPDOWN
PHSEN
TB_DISABLE
Phase loading disabled
PRDLD
TB_SHADOW
SYNCOSEL
TB_CTR_ZERO
Sync down-stream module
CMPCTL
SHDWAMODE
CC_SHADOW
SHDWBMODE
CC_SHADOW
LOADAMODE
CC_CTR_ZERO
Load on CTR = 0
LOADBMODE
CC_CTR_ZERO
Load on CTR = 0
AQCTLA
CAU
AQ_SET
Set actions for EPWM1A
CAD
AQ_CLEAR
DBCTL
MODE
DB_FULL_ENABLE
Enable Dead-band module
POLSEL
DB_ACTV_HIC
Active Hi complementary
DBFED
DBFED
50
FED = 50 TBCLKs
DBRED
50
RED = 50 TBCLKs
Table 16-43. EPWM2 Initialization for Figure 16-57
Register
Bit
Value
Comments
TBPRD
TBPRD
800 (320h)
Period = 1600 TBCLK counts
TBPHS
TBPHS
0
Clear Phase Register to 0
TBCTL
CTRMODE
TB_UPDOWN
PHSEN
TB_ENABLE
Slave module
PRDLD
TB_SHADOW
SYNCOSEL
TB_SYNC_IN
Sync flow-through
CMPCTL
SHDWAMODE
CC_SHADOW
SHDWBMODE
CC_SHADOW
LOADAMODE
CC_CTR_ZERO
Load on CTR = 0
LOADBMODE
CC_CTR_ZERO
Load on CTR = 0
AQCTLA
CAU
AQ_SET
Set actions for EPWM2A
CAD
AQ_CLEAR
DBCTL
MODE
DB_FULL_ENABLE
Enable Dead-band module
POLSEL
DB_ACTV_HIC
Active Hi complementary
DBFED
DBFED
50
FED = 50 TBCLKs
DBRED
50
RED = 50 TBCLKs