Liquid Crystal Display Controller (LCDC)
23.3.3 LCD Status Register (LCD_STAT)
The LCD status register (LCD_STAT) contains bits that signal status and error conditions to the
processor. Each of the LCD status bits signals an interrupt request as long as the bit is set AND the
interrupt enable for that bit is also set (see the LCD raster control and LCD DMA control registers for these
enables). Writing a 1 to each bit clears it; once the bit is cleared, the interrupt is cleared. The LCD_STAT
is shown in
and described in
Figure 23-17. LCD Status Register (LCD_STAT)
31
16
Reserved
R-0
15
10
9
8
7
6
5
4
3
2
1
0
Reserved
EOF1
EOF0
Rsvd
PL
FUF
Rsvd
ABC
SYNC
Rsvd
DONE
R-0
R/W-0
R/W-0
R-0
R/W-0
R/W-0
R-0
R/W-0
R/W-0
R-0
R/W-0
LEGEND: R = Read only; -
n
= value after reset
Table 23-13. LCD Status Register (LCD_STAT) Field Descriptions
Bit
Field
Value
Description
31-10
Reserved
0
Reserved
9
EOF1
End of Frame 1
0
no end of frame 1 detected
1
end of frame 1 detected
8
EOF0
End of Frame 0
0
no end of frame 0 detected
1
end of frame 0 detected
7
Reserved
0
Reserved
6
PL
Loaded Palette
0
The palette is not loaded
1
The palette is loaded
5
FUF
FIFO Underflow Status
0
FIFO has not underrun
1
LCD dither logic not supplying data to FIFO at a sufficient rate, FIFO has completely emptied and data
pin driver logic has attempted to take added data from FIFO
4
Reserved
0
Reserved
3
ABC
AC Bias Count Status
0
AC bias transition counter has not decremented to zero
1
AC bias transition counter has decremented to zero, indicating that the LCD_AC_O line has transitioned
the number of times that is specified by the ACB_I control bit field. Counter is reloaded with value in
ACB_I but is disabled until the user clears ABC.
2
SYNC
Sync Lost
0
normal
1
Frame Synchronization Lost has occurred
1
Reserved
0
Reserved
0
DONE
Raster or LIDD Frame Done (shared; depends on whether Raster or LIDD mode enabled)
0
Raster or DMA_to_LIDD engine is enabled
1
Raster or DMA_to_LIDD disabled and the active frame has just completed