![Texas Instruments AM1808 Скачать руководство пользователя страница 1387](http://html.mh-extra.com/html/texas-instruments/am1808/am1808_technical-reference-manual_10945581387.webp)
Registers
1387
SPRUH82C – April 2013 – Revised September 2016
Copyright © 2013–2016, Texas Instruments Incorporated
Serial ATA (SATA) Controller
28.4.15 Global Parameter 2 Register (GPARAM2R)
The global parameter 2 register (GPARAM2R) is a read-only register that contains encoded information
about the configuration of the embedded Synopsis AHCI SATA Core. The GPARAM2R is shown in
and described in
.
Figure 28-15. Global Parameter 2 Register (GPARAM2R)
31
16
Reserved
R-0
15
14
13
12
11
10
9
Reserved
DEV_CP
DEV_MP
ENCODE_M
RXOOB_CLK_M
RXOOB_M
TX_OOB_M
R-0
R-1
R-1
R-1
R-0
R-0
R-1
8
0
RXOOB_CLK
R-96h
LEGEND: R = Read only; -
n
= value after reset
Table 28-19. Global Parameter 2 Register (GPARAM2R) Field Descriptions
Bit
Field
Value
Description
31-15
Reserved
0
Reserved.
14
DEV_CP
1
Cold Presence Detect. CPD is supported in SATASS.
13
DEV_MP
1
Mechanical Presence Switch. MP is supported in SATASS.
12
ENCODE_M
1
8b/10b Encoding/Decoding. Indicates 8-bit/10-bit encoding and decoding are done in the Synopsis
core.
11
RXOOB_CLK_M
0
Rx OOB Clock Mode. Indicates that the Rx OOB Functions are on the Rx Clock.
10
RX_OOB_M
0
Rx OOB Mode. Indicates that Rx Out-of-Band signals are detected in the phy.
9
TX_OOB_M
1
Tx OOB Mode. Indicates that Tx Out-of-Band signaling is done by the Synopsis Core.
8-0
RXOOB_CLK
96h
Rx OOB Clock Frequency. Reflects the hexadecimal value of the RXOOB_CLK_FREQ parameter.