![Texas Instruments AM1808 Скачать руководство пользователя страница 429](http://html.mh-extra.com/html/texas-instruments/am1808/am1808_technical-reference-manual_1094558429.webp)
SYNCI
CTR=PRD
Disable
Disable
Sync out
select
ECCTL2[SYNCOSEL]
SYNCO
ECCTL2[SWSYNC]
SYNC
ECCTL2[SYNCI_EN]
CTRPHS
LD_CTRPHS
CLK
TSCTR
(counter 32b)
RST
OVF
SYSCLK
Delta−mode
CTR−OVF
CTR[31−0]
Architecture
429
SPRUH82C – April 2013 – Revised September 2016
Copyright © 2013–2016, Texas Instruments Incorporated
Enhanced Capture (eCAP) Module
15.2.2.4 32-Bit Counter and Phase Control
This counter (
) provides the time-base for event captures, and is clocked via the system clock.
A phase register is provided to achieve synchronization with other counters, via a hardware and software
forced sync. This is useful in APWM mode when a phase offset between modules is needed.
On any of the four event loads, an option to reset the 32-bit counter is given. This is useful for time
difference capture. The 32-bit counter value is captured first, then it is reset to 0 by any of the LD1-LD4
signals.
Figure 15-7. Counter and Synchronization Block Diagram