MPU Registers
111
SPRUH82C – April 2013 – Revised September 2016
Copyright © 2013–2016, Texas Instruments Incorporated
Memory Protection Unit (MPU)
5.3.11 Programmable Range n End Address Registers (PROGn_MPEAR)
The programmable range
n
end address register (PROG
n
_MPEAR) holds the end address for the range
n
. This register is writeable by a supervisor entity only.
The end address must be aligned on a page boundary. The size of the page depends on the MPU: the
page size for MPU1 is 1 KByte; the page size for MPU2 is 64 KBytes. The size of the page determines the
width of the address field in the programmable range
n
start address register (PROG
n
_MPSAR) and
PROG
n
_MPEAR. For example, to protect a 64-KB page starting at byte address 8001 0000h, write
8001 0000h to PROG
n
_MPSAR and 8001 FFFFh to PROG
n
_MPEAR.
5.3.11.1 MPU1 Programmable Range n End Address Register (PROG1_MPEAR-PROG6_MPEAR)
The PROG
n
_MPEAR for MPU1 is shown in
and described in
Figure 5-14. MPU1 Programmable Range n End Address Register (PROGn_MPEAR)
31
10
9
0
END_ADDR
Reserved
R/W-20 007Fh
R-3FFh
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 5-17. MPU1 Programmable Range n End Address Register (PROGn_MPEAR)
Field Descriptions
Bit
Field
Value
Description
31-10
END_ADDR
20 0000h–
20 007Fh
End address for range N.
9-0
Reserved
3FFh
Reserved
5.3.11.2 MPU2 Programmable Range n End Address Register (PROG1_MPEAR-PROG12_MPEAR)
The PROG
n
_MPEAR for MPU2 is shown in
and described in
Figure 5-15. MPU2 Programmable Range n End Address Register (PROGn_MPEAR)
31
16 15
0
END_ADDR
Reserved
R/W-DFFFh
R-FFFFh
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 5-18. MPU2 Programmable Range n End Address Register (PROGn_MPEAR)
Field Descriptions
Bit
Field
Value
Description
31-16
END_ADDR
C000h–DFFFh
Start address for range N.
15-0
Reserved
FFFFh
Reserved