Neuromuscular transmission
2.
Select
Start with
>
Current patient
.
3.
Select
Continue
.
Restarting the NMT measurement in OR after induction
When you move the patient with the module to the OR and want to continue the
measurement with the already found and determined current and reference values,
use the restart function. Connect the module to the monitor and press the
Stop
Continue
module key, or:
1.
Select the NMT parameter window >
Setup
.
2.
Select
Start with
>
Recall reference
.
3.
Select
Restart
.
Stopping the NMT measurement
Press the
Stop Continue
module key, or:
1.
Select the NMT parameter window >
Setup
.
2.
Select
Stop
.
NMT alternative uses
Local nerve and plexus localization
Single stimulation pulses may be helpful for determining the correct needle tip position
from a local nerve in plexus procedures. The NMT module delivers single stimulation
pulses at a selected rate until it is manually stopped. Muscle contractions from the
stimulated innervating motoric nerve(s) may be observed. Note that you need specific
accessories for this measurement.
2062971-001
CARESCAPE Modular Monitors
367
Содержание CARESCAPE
Страница 38: ...38 CARESCAPE Modular Monitors 2062971 001 ...
Страница 114: ...Setting up the monitor before use 114 CARESCAPE Modular Monitors 2062971 001 ...
Страница 146: ...Alarms 146 CARESCAPE Modular Monitors 2062971 001 ...
Страница 218: ...Pulse oximetry 218 CARESCAPE Modular Monitors 2062971 001 ...
Страница 234: ...Non invasive blood pressure 234 CARESCAPE Modular Monitors 2062971 001 ...
Страница 260: ...Temperature 260 CARESCAPE Modular Monitors 2062971 001 ...
Страница 274: ...Cardiac output 274 CARESCAPE Modular Monitors 2062971 001 ...
Страница 280: ...Mixed venous oxygen saturation SvO 280 CARESCAPE Modular Monitors 2062971 001 ...
Страница 322: ...CO2 with CAPNOSTAT Mainstream CapnoFlex LF and Dual CO2 modules 322 CARESCAPE Modular Monitors 2062971 001 ...
Страница 338: ...Patient Spirometry 338 CARESCAPE Modular Monitors 2062971 001 ...
Страница 372: ...Neuromuscular transmission 372 CARESCAPE Modular Monitors 2062971 001 ...
Страница 404: ...Laboratory data 404 CARESCAPE Modular Monitors 2062971 001 ...
Страница 410: ...Calculations 410 CARESCAPE Modular Monitors 2062971 001 ...
Страница 416: ...Drug calculations 416 CARESCAPE Modular Monitors 2062971 001 ...
Страница 424: ...Trends 424 CARESCAPE Modular Monitors 2062971 001 ...
Страница 432: ...Snapshots and events 432 CARESCAPE Modular Monitors 2062971 001 ...
Страница 462: ...Cleaning and care 462 CARESCAPE Modular Monitors 2062971 001 ...
Страница 528: ...Abbreviations yr year yrs years 528 CARESCAPE Modular Monitors 2062971 001 ...
Страница 546: ...Skills checklist 546 CARESCAPE Modular Monitors 2062971 001 ...
Страница 547: ...content ...