Installer Menu Options
i-on Range
Page 64
Type:
(nn=shortcut)
Active when:
Assign to
Partitions?
Note: To cause the control unit to check its
backup battery use the
Test - Battery(s) -
Panel
option (see page 126).
External PSU
Low Volts (14)
30 40 50
160
An external power supply has triggered an
External PSU Low Volts zone.
The control unit deactivates the output
when the zone has been restored and a
user has acknowledges the fault by
entering a valid access code.
No
External PSU
Fault (15)
30 40 50
160
An external power supply fault signal
triggers a Power output fault zone.
The control unit deactivates the output
when the zone has been restored and a
user has acknowledges the fault by
entering a valid access code.
No
Tamper (16)
The control unit detects tamper on any the
following devices:
Control unit, lid or wall tamper.
Radio or wired keypad.
Zone type ―Tamper‖ activates.
Detectors or Expanders
Sounders
The control unit deactivates the output
when tamper is reset.
Yes
Zone Omit
(Setting) (17)
The user Omits a zone while setting the
system. The output deactivates when the
control unit restores the zone.
Yes
Zone Omit
(System) (18)
(Operates only when DD243 or BS8243 is
enabled.) In the event of an unconfirmed
alarm,
the system will rearm itself when
the confirmation timer expires. If the zone
that caused the unconfirmed alarm is still
active at the time of the rearm, the control
unit will omit that zone and activate the
output. The control unit will restore the
zone and output when a user or engineer
resets the system.
Yes