i-onEX Range
Page 29
Installer Menu
Important
: Where noted below the defaults listed enable the control unit to
comply with EN50131 requirements. If you change those settings then the
installation may no longer comply. If the control unit does not comply with
EN50131 you must remove any labelling that indicates compliance.
MENU Option
Factory Default
Notes
1 DETECTORS/ DEVICES
Detectors
Add/Del Detectors
Exp. R1-nn
30 50 160
First radio expander with
spare zones
Appears only if a radio
expander is available on the
bus.
Zone number depends on
expander number.
Zone nnn...
Delete all
Program Zones
Zone 000...159
(see note)
Actual number of zones
depends on panel type and
expanders fitted.
Name
―Zone nnn‖
Type
Not used
Partitions
None
30 40 50 160
Appears only in a Partitioned
system and when zones have
a type other than ―Not Used‖.
Attributes
Chime: No
Soak Test: No (not i-on16)
Double Knock: No (not i-on16)
Part Set B: No (level setting system only)
Part Set C: No (level setting system only)
Part Set D: No (level setting system only)
Part Set: No (partition system only, not
on i-on16)
Omittable: No
Force Set Omit: No
Masking: No (not i-on16)
Inverted: No (not i-on16)
Roller Shutter: No (see notes)
Appears when zone is given a
type other than ―Not Used‖.
Some attributes are only
available on particular zone
types.
Double Knock does not comply
with EN51031.
Masking must enabled in
System Options.
(Roller Shutter is available
only on i-on160EXEUR.)
Address Bus Devices
30 50 160
Wired Expanders
30 50 160
Address Bus Device
Edit Expander
Expander W1-01...W1-45
Display shows expanders
currently addressed on bus.
Max number depends on
control unit type.
Name
―Exp. W1-nn‖
nn is between 01 and 45,
depending on control unit
type.
Partitions
Partition 1.
Appears only in a partitioned
system.
Wired zone type
FSL 2k2/4k7