i-on Range
Step by Step Programming Procedures
Page 137
7. Press
or
until the display shows the
expander you wish to replace (in this example,
expander W1-04):
8. Press
.
The display shows:
Notes:
1. If you change your mind and do NOT wish to
replace the expander then press
.
9. Press
.
The display shows for a few seconds:
Followed by:
The navigation keys on the keypad glow red.
10 a) Power down the system (both mains and
battery).
b) Remove the old expander.
c) Connect the new expander.
Note: The new expander must be of the same type
as the one you removed. Make sure that you
replace an EXP-R30 with an EXP-R30.
d) Power up the system (connect the battery,
close the control unit lid to ensure the tamper
switch is closed, then apply mains power).
The keypad display shows:
The navigation key LEDs glow red to show that
there is an alert for the disabled expander.
11. Re-enter Installer Men, and navigate back to
Detectors/Devices – Wired Expander – Replace
Expander
(follow steps 1 to 6).
The display shows:
12. Press
.
The display shows:
13. Go to the expander. Remove the expander lid.
Hold down the Request/Delete Address button
for at least three seconds.
After three seconds the expander gives a
confirmation tone (two beeps) and its display shows
the address allocated by the control unit. In this
example the address is 1-04; the control unit has
allocated the address of the old expander.
1-
followed by
04
Содержание i-On 40
Страница 1: ......
Страница 10: ...i on Range Page x This page is intentionally blank...