i-on Range
The Installer Menu
Page 35
After Entry
1 zones
Visible for DD243 or BS8243.
Default changes to 2 zones
when Confirmation Mode =
DD243.
Entry Keypad Lock
Off
Visible for DD243 or BS8243.
Sounder on
Unconfirmed
Visible for DD243, BS8243 and
Basic.
Siren on
Unconfirmed
Visible for DD243, BS8243 and
Basic.
Unconfirmed reset
User
Visible for DD243 or BS8243.
Confirmed reset
User
Visible for DD243 or BS8243.
HUA Confirm time
8 hours
Visible for BS8243 only.
Must
be between 8 and 20 hours in
order to comply with
BS8243:2010
Profiles
16
40
Masking
Grade 2: Off
Grade 3: On
30
40 50 160
Masking
“ON” is required in order to
comply with EN50131-1,
8.2.1.
Mask Override
On
30
40 50 160 Appears
only when Masking is On.
Language
English
This option does not appear in
UK versions.
Restore Defaults
Staged defaults
30 50 160
i-on30EX cannot change to 6-
digit user codes.
Factory defaults
Country Defaults
Appears on EUR systems only,
as part of Factory Default
process.
Installer Name
―Installer‖
Installer Code
Grade 2: ―7890‖
Grade 3, ―567890‖
i-on16, i-on30EX, and i-on40
Grade 2 only.
Keypad text
Depends on control unit type.
Remote Needs Entry
Disabled
HUA Response
Audible
Appears here only in part
setting system.
Auto Rearm
Never
This setting is required in
order to comply with
EN50131.
Appears only when System
Options – Confirmation Mode
is ―Basic‖.
Panel Loudspeaker
Loudspeaker 1 (or 2)
(Two loudspeakers on i-
on160EX.)
Volume
****
Partitions
01...04 (i-on30)
01...04 (i-on40)
01...05 (i-on50)
01...20 (i-on160)
Yes
30
40 50 160
Appears
only in a Partitioned system.
Assigned to all partitions.
Number of partitions depends
on panel type.
Entry Alarm Delay
Enabled
This setting is required in
order to comply with EN50131
8.3.8.2.
Abort Time
120 seconds
Supervision
Tamper
Содержание i-On 40
Страница 1: ......