The System Bus
i-on Range
Page 22
one device the numbers R1-02, R1-03 and R1-04. In the Installer menu the
keypad display shows only ―R1-02‖ but also adds the characters ―(R30)‖ at the
end of the line as a reminder.
Figure 4. Bus Device Addressing for EXP-R30.
Note that you can connect an i-on30EX to an EXP-R30, but you will not be able
to use all the zone available on the EXP-R30 (see ―Zone Numbering‖ on page
25)
Detector Connection Point Addresses
Each connection point for a detector has an address. This address is an
extension of the bus device address.
The control unit shows the connection point address as three groups of
characters:
An<dd<ii
An<dd The first two groups are the address of the bus device, see the
previous page. The ―A‖ can be either ―R‖ for a radio expander or ―W‖
for a wired expander.
<
The ―<‖ character is a reminder that the address is a detector (a form
of input).
ii =
The last group is the input number. For wired expanders this can be
any number from 0 to 9. For radio expanders this can be any number
from 0 to 9 for the EXP-R10, or 00 to 29 for the EXP-R30.
The detector connection points on the control unit PCB are numbered
P0<00<00 to P0<00<09 (FSL wiring) or P0<00<01 to P0<00<05 (CCL
wiring).
See Figure 5 for examples: