Installer Menu Options
Page 101
4. Burglar Alarm (default Channel 3)
5. Open/Close (default Channel 4)
6. Alarm Abort (default Channel 6)
7. Technical Alarm (default Channel 8)
8. Confirmed Alarm (default Channel 7)
9. RF Low Battery
10. RF Supervision (see note 5)
11. RF Jamming (see note 5)
12. Mains Fail (see note 6)
13. Tamper
14. Open (see note 1)
15. Close (see note 1)
16. Zone Omitted - setting (default Channel 5. see note 2)
17. Zone Omitted - system (see note 4)
18. General Fault
19. Masking
20. Burg Partition 1 (partioned system only)
.. and so on up to the maximum number of partitions handled by the
control unit. For example on an i-on160:
39. Burg Partition 20 (partioned system only)
Notes:
1.
Open and Close provide the same functions as Open/Close, but on two
separate channels.
2.
Zone Omitted - the control unit sends this signal for five seconds when a
user omits a zone.
3.
The control unit delays reporting/logging either mains loss, or exiting
Installer Menu with mains loss, by 15-18 min (chosen randomly). For
Scandinavia the control unit waits at least 60 minutes before reporting.
4.
Appears only when DD243 or BS8243 options enabled.
5.
The control unit communicates Jamming, Supervision when the system is
unset.
6.
The control unit sends a Mains Fail when Either mains power is absent,
OR a zone of type “External PSU A/C Fail” has been triggered. The control
unit sends a restore if a user keys in a valid access code after mains
power has been restored.
The time at which the control unit operates an A/C Fail output varies as
follows:
a) If EITHER mains is present at the control unit but not the external PSU
OR has been absent at the control unit for more than 10s then the control
unit sends Mains Fail.
b) If mains fails at the control unit at the same time as an external PSU
triggers the External PSU A/C Fail zone input (+/- 10s) then the control