Introduction
i-on Range
Page 6
i-gsm02 A GSM module that allows speech messaging, alarm reporting and
SMS text messaging over the mobile phone network.
To ensure that the i-on16, i-on30EX, i-on40, i-on50EX and i-on160EX comply
with EN50131 you must fit a suitable communicator.
The i-on30EXD also has a built-in digital communicator. Note that this
communicator is disabled if you fit a plug-on module.
Programming the System
As an installer you can program the system in any of three separate ways:
a) From the keypad.
b)
30 40 50 160
From a PC or laptop connected to the control unit either
over the PSTN or via the USB port, using i-on Downloader software.
c)
40 50 160
From a PC or laptop connected to the control unit via
Ethernet cable, and using a web browser (IE 8 recommended). This option
is not available on the i-on30EX.
This manual describes programming the control unit from the keypad. The
settings and options provided through the web server or i-on Downloader have
the same functionality as those provided through the keypad.
Part Setting or Partitioned System
An i-on control unit offers two basic ways of behaving as an alarm system:
Part Set Mode
. In Part Set Mode the control unit can set in one of four ways:
either Full set or three varieties of Part Set. In Full Set the control unit pays
attention to all detectors. In each of the three Part Sets, the control unit
ignores all detectors that do not have the appropriate Part Set attribute
enabled (see page 47 ).
Partition Mode
.
30 40 50 160
In Partition Mode the control unit
provides the equivalent of a set of smaller, independent alarm systems. Each
system is a ―Partition‖ of the whole. You can allocate any set of zones to each
Partition. Each zone can also belong to more than one Partition. Each Partition
can have a Full Set level and one Part Set level. During programming the
installer can allocate keypads, sounders or outputs to any of the partitions.
The i-on160EX supports 20 partitions, the i-on50EX supports five, and the i-
on30EX and i-on40 support four partitions.
System Security Grade
All i-on control units are suitable for use in systems conforming to Security
Grade 2 requirements.
The i-on50EX and i-on160EX can be used in either Security Grade 2 or 3 alarm
systems.
50 160
During initial power up (and if you reset a system to factory
defaults) the i-on50EX and i-on160EX control units provide an opportunity for
you to set various system options in one step in order to program the system
for either Security Grade 2 or Security Grade 3.