i-on Range
Installer Menu Options
Page 121
principal voltage regulator. If it shows anything other
than 13.6V then this indicates that there may be either
a mains ―brown out‖ or that the expander is running on
its standby battery.
Aux 1 Voltage
This option shows the voltage on the 12V line of the
Aux 1 terminals.
Aux 2 Voltage
This option shows the voltage on the 12V line of the
Aux 1 terminals.
Comms O/P voltage
This option shows the voltage on the 12V positive
terminal of the plug-by communications connector.
Bus Voltage
This option shows the voltage on the 12V line of the
system bus going out of the expander.
Load Current
This shows the total current drawn by Aux 1, Aux 2,
Comms O/P 12V supply, and the bus out 12V supply.
Mains Condition
This option shows the condition of the mains power at
the expander. It shows ―Healthy‖ when mains is present
or ―Missing‖ when mains is absent.
Battery 1 Status
This option shows the condition of battery 1. ―Health‖
means battery present, in good condition and charged.
―Low‖ mean battery present but discharged. ―Missing‖
means battery is not connected.
Battery 2 Status
160
This option will be present if you have enabled battery 2
monitoring in
System Option – Battery 2
(see page 95).
The option shows ―Healthy‖, ―Low‖ and ―Missing‖ with
the same meanings as in Battery 1 Status.
Walk test
The walk test menu provides several different ways of organising a walk test.
The options within Walk Test are:
Chime
Use this option to turn a chime tone on or off. When the
chime tone is on, the keypads and loudspeakers will
sound a chime tone for each zone that triggers while
you are performing a walk test.
System
This option allows you to walk round the entire system
and test all the zones.
Partitions
30 40 50 160
Use this option to select one or more partitions, and
test the zones only within those partitions.
Use
u
or
n
to scroll up and down the list of partitions.
Press
or
to display ―Yes‖ at the end of the bottom
line to mark the partition as one you want to test.
Expanders
30 50 160
Use this option to select an individual expander, and
test the zones belonging to just that expander.