Installer Menu Options
i-on Range
Page 68
Type:
(nn=shortcut)
Active when:
Assign to
Partitions?
HUA Confirm
(48)
(Operates only when BS8243 is enabled.)
A confirmed Hold Up Alarm (HUA) has
occurred. The control unit activates this
output when users have activated two
separate Hold Up Devices (HUDs) within
the HUA confirmation time. You can assign
this output to one or more partitions. Note
that the HUDs must both be in the same
partitions as the output. The control unit
deactivates the output when a user or
engineer resets the system.
Lock Set
Unlocked (49)
A Lock Set zone is active. The control unit
activates the output when the Lock Set
zone is activated, and deactivates the
output when a Lock Set zone is
deactivated.
Burg Confirm
timer (50)
(Operates only when DD243 is enabled.)
Burg confirmation timer is running.
Inactive when the timer stops. This option
is not available –EUR versions.
HUA confirm
timer (51)
(Operates only when BS8243 is enabled.)
HUA confirmation timer is running. Inactive
when the timer stops. This option is not
available –EUR versions.
Rearmed (52)
In a part setting system the control unit
activates the output if the system re-arms
at least once after the user armed it. If
Confirmation Mode is set to DD243 or
BS8243 then the control unit activates the
output as it rearms the system after the
confirmation timer expires. If Confirmation
Mode is set to Basic then the control unit
activates the output as it rearms the
system when the bell/siren time expires.
In a partitioned system you can allocate
the output to individual partitions.
The control unit deactivates the output
when a user or installer resets the
system/partition.
Programming User Defined Outputs
Output type 43 allows you to program User Defined Outputs.
User Defined outputs can be activated by one of the following events:
A user presses a button on a remote that has been programmed to activate
a User Defined output.