i-on Range
Basic Programming Procedures
Page 11
Master User has entered the User menu, or if an installer has already entered
the Installer Menu from a keypad.
To Enter the Installer Menu:
1. Make sure the system is fully unset and
showing the standby screen (time and date).
Note that although the example at the right shows
“i-on160EX” on the top line, if you are using
another control unit, the text will show the
name of that control unit.
2. Key in the Installer access code. When delivered
from the factory, at Security Grade 2 the
default Installer access code is ―7890‖. The
default user code is ―1234‖. (Note that at
Security Grade 3 on the i-on50EX and i-
on160EX the codes are ―567890‖ and ―123456‖
respectively.)
As you start to key in the code the display
shows:
When you key in the last digit of the access
code the display MAY show:
If this happens key in a valid user code (not a
Set Only user code see note 1).
When you key in the last digit of the access
code the display shows ―Installer Menu‖ on the
top line. The bottom line shows the first option
in the Installer menu: Detectors/Devices. (See
note 2.)
3. Press
or
to display more options from the
menu.
Each option appears on the bottom line of the
display in turn, for example:
4. Press
or
to select that option of the menu.
The option you selected now appears on the top
line. If there are any sub-options for that
selection, then the first of them appears on the
bottom line. Press
or
to display the other
sub-options.
Notes:
1. After you initially gain access to the Installer Menu, you may leave and
re-enter using the Installer access code by itself for up to 30 minutes
after you last exited the Installer Menu. After that time, or if the system
is armed then disarmed, you will need to enter a valid user access code to
complete your entry into the Installer Menu (note that you cannot use a
Содержание i-On 40
Страница 1: ......
Страница 10: ...i on Range Page x This page is intentionally blank...