Installer Menu Options
i-on Range
Page 60
The software in an i-onEX range control unit can only handle a maximum
number of outputs in total. The table on page 8 gives the totals for each type
of control unit.
If the number of physical hardwired outputs attached to the system exceeds
this maximum then the installer menu will not let you program some of those
outputs.
Bell and Strobe
You can program the behaviour of the dedicated Bell and Strobe outputs on
the control unit PCB with the following options:
Name
You can assign a 12 character name to the Bell and Strobe
outputs.
Polarity
You change the polarity of either output, to suit the type of
equipment that the output must work with. There are two options:
Normal.
The output is held at +12V while inactive, and at 0V
when activated.
Inverted.
The output is held at 0V while inactive, and at +12V
when activated.
Partition
30 40 50 160
In a partitioned system you can assign the
outputs to any of the partitions.
Wired Outputs
To use wired outputs you must program their behaviour by giving them an
output type. See page 61 for a list of the output types available. See page 168
for detailed instructions on how to change the type. You can also give each
wired output a name (see page 168) and assign the output to one or more
partitions. (By default wired outputs are assigned to all partitions in a
partitioned system.)
Polarity
30 40 50 160
The control unit lets you change the polarity of each wired output, to suit the
type of equipment that the output must work with. There are two options:
Normal
The output is held at +12V while inactive, and at 0V when activated.
Inverted
The output is held at 0V while inactive, and at +12V when activated.
For instructions on how to change the polarity , see page 172.
Control Unit Plug-By Outputs
30 40 50 160
The plug-by outputs on the control unit are designed for use by standalone
communicators (see the relevant
Installation Guide
for connection details). You
can give each output a name, a type, and change its polarity. Programming
plug-by outputs is the same as programming wired outputs, but you must use
the
Outputs – Plug-by Outputs
menu.