i-on Range
Installer Menu Options
Page 95
Tamper Omit
If a user omits a zone, it may be necessary to also omit the tamper belonging
to that zone. This option allows you to do that:
Enabled
The tamper is omitted when a user omits a zone.
Disabled
The tamper is still operational when a user omits a zone.
CSID Code (Anti-Code Reset)
Anti-code reset allows an alarm company to control remotely whether a user
can reset the system after an alarm. If the system is programmed for anti-
code reset, then after an alarm a user can silence the sounders. However, the
display tells the user the first zone to alarm, and then instructs them to call the
ARC and quote a four digit code. This four digit code is called the ―reset code‖.
If the ARC decides to allow the user to reset the system then they:
Key the reset code into a device or program that produces an ―anti-code‖.
Tell the alarm system user the anti-code.
The alarm system user then keys the anti-code into their keypad and the alarm
system resets.
If order for this procedure to work both the alarm system control unit and the
ARC must have the same ―CSID‖ code. This acts as a seed for computing both
the reset code and its anti-code. The ARC usually generates the CSID code.
Use this option to program the control unit with the CSID required for anti-
code reset. If you set the CSID to ―0000‖ then the control unit will not use
anti-code reset. If you sent the CSID to any number 0001 to 9999 then the
control unit will use anti-code reset.
Silence Alerts
This option controls the length of time that the keypad gives the alert tone (a
brief ‗beep‘ every few minutes) when there is an alert. The options are:
User
The keypad gives the tone until a user keys in their access code to
acknowledge the alert.
30, 60, 120 minutes
The keypad gives the alert tone for the selected time. The status LEDs on
the Navigation key stay on for the selected time. The alert tone stops if a
user enters a valid access code.
No Alert Tones
The keypad gives no alert tone. (The red LEDs around the navigation key
glow to show that there is an alert.)
Mains Fail Delay
This option controls the length of time that the control unit waits after
experiencing a mains supply failure until reporting Mains Fail and starting an
alert at the keypads. The values available are 0 to 60 minutes.