i-on Range
Installer Menu Options
Page 41
Deleting a Single Detector
To delete an individual detector select
Detectors/Devices - Detectors – Add/Delete
Detectors
from the Installer Menu. See page 143 for detailed instructions.
There are two options:
Delete Detector ID
Use this option to make the control unit ―forget‖ the ID of the detector,
but leave any zone programming in place.
Default zone
If you select this option then the control unit ―forgets‖ the ID of the
detector
and
sets all the zone programming back to default values: Type
= Not Used, no attributes.
Notes:
1. A “*” indicates that the control unit has learned a radio detector
learned for that zone.
2. The deletion will take place immediately, and not when you leave
Installer Mode.
Program Zones
You can program each zone's behaviour at any time, whether or not a wired
detector is connected, or the control unit has learned the identity of a radio
detector. See page 145 for detailed instructions.
Notes:
1. If a wired zone does not have a detector connected to it then make
sure that you set the zone type to “Not Used”. When delivered from the
factory the control unit has all zones set to “Not Used”.
2. If you program a radio zone but the control unit does not have a
detector learned for that zone then the keypad will display “Zone
programmed but not learned” when you leave Installer Mode.
Changing Zone Names
You can give each zone a 12 character name to help you remember its purpose
or location. The control unit displays this name in first to alarm and keypad
fault displays, or when you program the zone at a later date. Use
Detectors/Devices - Detectors – Program Zones.
See page 145 for detailed
instructions.
For hints on editing zone names see page 18.
Zone Types
When programming zone types the bottom line of the keypad display shows a
―*‖ at the left of the zone‘s current type.
You can select a zone type quickly by keying the two digit shortcut number
shown in brackets after the type‘s name in the list below. For example: key in
―05‖ to select Final Exit, ―02‖ to select Fire Alarm, ―11‖ to select External PSU
A/C Fail. The number does not appear on the keypad display.
The list below shows the available zone types. When the description mentions
―system‖ then this means either the alarm system itself in a part setting
system, or those partitions the zone is allocated to in a partitioned system.