i-on Range
Installer Menu Options
Page 75
outputs or HUA outputs remain inactive. The control unit
signals the HUA using the communications device(s).
Displayed
All keypads display a HUA alert message immediately (a
user does not have to key in their access code to see the
message). If more than one HUA is active then the keypad
display scrolls through the alert messages at roughly one
second intervals.
The control unit also starts HUA alarm tones, activates any
siren and HUA outputs, and starts communications, as
described for the ―Audible‖ option.
Notes:
1. All HUAs are disabled when the system is in Installer Menu.
2 In a partitioned system the HUA Response option applies to both the Full Set
partition and the Part Set Partition.
Siren Delay
When the system (or partition) is set and (for example) an intruder violates a
zone, then the system waits for the programmed Siren Delay before operating
the siren and sounders. The system then operates the siren and sounders for
the programmed Siren Time.
Notes:
1. Siren Delay has no effect if the Alarm Response Mode does not require
communications or if a line fault is detected.
2. Siren Delay also has no effect if System Options – Confirmation Mode
is set to DD243 or BS8243 AND System Options – Confirmation – Siren
On is set to “Unconfirm” (see page 86).
3. Any keypad sounder or expander sounder assigned to two or more
partitions uses the shortest Siren Delay of the partitions the sounder is
assigned to.
Siren Time
This option changes the length of time that the system operates the siren and
sounders during an alarm.
Notes:
1. The durations offered by the display apply to a siren wired directly to
the control unit.
2. The 760ES radio siren has one of three fixed sounder durations in an
alarm: 5 seconds, 3 mins or 15 mins. These fixed durations are designed
to preserve the battery life of the radio siren.
3. Any keypad sounder or expander sounder assigned to two or more
partitions uses the longest Siren Time of the partitions the sounder is
assigned to. The time that the sounders are active for may also be
extended by the longest of the Siren Delays that the assigned partitions
possess.
Part Set Final Exit As
This option controls how the system will treat Final Exit zones in a part set.