i-on Range
Installer Menu Options
Page 47
are disabled for 14 days after you return the control unit to user/unset
mode. If the zone remains inactive for the whole fourteen days then after
midnight on the 14th day the control unit returns the zone to normal use.
If the zone is activated during those 14 days while the system is set then
the control unit logs the event as a ―Soak Fail Znnn Alm‖ (nnn is the zone
number, see page 23) without sounding any sirens or starting
communications. The control unit also lights the red LEDs around the
navigation key on the keypad to alert the user when they unset the
system. An installer must key in their access code to reset the alert.
During setting the keypad displays a brief message to inform the user that
one or more zones are in soak test.
You can use this attribute on the following zones types: Normal Alarm,
Entry Route and Tamper.
Double Knock
30 40 50 160
Zones programmed with this attribute will cause an alarm only if the zone
is EITHER triggered, restored and triggered again within a five minute
period, OR if the zone remains active for 10 seconds.
You can apply the Double Knock attribute to the Normal Alarm and, Entry
Route zone types.
Note: Double Knock does not comply with EN50131.
Part Set B
(Not visible in a partitioned system.) When a user presses button B (part
set), the control unit sets only those zones where the Part Set B attribute
= ―Yes‖. (See also ―Part Set Exit Mode‖ on page 71 ).
You can apply this attribute to the following zone types: Normal Alarm,
Final Exit and Entry Route.
Part Set C
(Not visible in a partitioned system.) When a user presses button C the
control unit sets only those zones where Part Set C attribute = ―Yes‖.
You can apply this attribute to the following zone types: Normal Alarm,
Final Exit and Entry Route.
Part Set D
(Not visible in a partitioned system.) When a user presses button D the
control unit sets only those zones where Part Set D attribute = ―Yes‖.
You can apply this attribute to the following zone types: Normal Alarm,
Final Exit and Entry Route.
Part Set
(Only visible in a Partioned system.) When a partition is Part Set, zones in
that partition with this attribute are set. Note that if a zone is in more
than one partition, all partitions have to be set or part set before this zone
will be set.
You can apply this attribute to the following zone types: Normal Alarm,
Final Exit and Entry Route.
Omittable
A) When a zone has this attribute, a user can omit it before setting the
system.