i-on Range
Installer Menu Options
Page 59
Enabling the Ready to Set LED
The Info Module possesses a LED that glows when the alarm system is NOT
ready to set (for example, because a detector is reporting an alarm). To
disable or enable this LED select
Detectors/Devices – Info Module - Ready-to-Set
LED
. The available options are:
Enabled
The control unit carries on using the Ready to Set LED on the
Info Module.
Disabled
The control unit stops using the Ready to Set LED the Info
Module.
WAMs
30 40 50 160
Each control unit in the i-onEX range can learn the maximum number given on
page 8.
Although the WAM provides five different modes, when working with an i-onEX
range control unit only mode 1, repeater module, is relevant. The installer
must select the repeater mode when commissioning the WAM hardware.
Note: i-on40 Release 4 uses WAMs as repeaters only.
When working as a repeater module the WAM repeats the signals from any
detectors within its range, amplifying them to a level that the control unit can
detect. This allows you to increase the area covered by detectors.
Naming WAMs
Use the Edit WAM option to give each WAM a meaningful name. The name can
be up to 12 characters long.
Outputs
The control unit provides three different sets of outputs:
Dedicated Bell and Strobe outputs.
Plug-by outputs.
Hardwired outputs.
(See the relevant
Installation Guide
for the position of connectors.)
See ―System Capacities‖ on page 8 for a list of the number of outputs provided
by each control unit.
30 50 160
In addition to the outputs wired directly into the control unit,
expanders also provide outputs:
Each wired expander provides 4 outputs on its PCB.
Radio expanders each provide 8 radio output channels.
The hardwired outputs on both on the control unit and expanders together with
the radio outputs on the expanders can be programmed as any of the output
types listed on page 61.